LINK Systems OmniLink - PLC Interface User Manual

Page 12

Advertising
background image

June 5, 2000

Man ual Rev 1 .0

2.4

The example above can be taken one additional step, if two press operators are given different user
names and different passwords. One operator can be assigned the ability to change tonnage monitor
limits in addition to the ability to reset tonnage monitor faults, while the other operator is not assigned
the ability to change the tonnage monitor limits.

Section 2.2.3 Password Only Mode

The “Password Only” mode allows for sixteen users. Each user can be assigned access to some or all of
the restricted items. This mode does not use the RUN/PROG key.

The example listed above indicated that setup personnel required access to all restricted items. In the
“Key or Password” mode, the setup personnel used the RUN/PROG key to gain access to all of the
restricted items. In the “Password Only” mode, the setup personnel can still have access to all of the
restricted items, but the system must be configured as such. The setup personnel must be assigned a user
name and password. In addition, all restricted items would be assigned access to the setup personnel.

Section 2.2.4 Key and Password Mode

The “Key and Password” mode requires the user to have the RUN/PROG key, user name, and user
password. Operation is basically the same as the Password only mode, except that in addition to
entering the password the user must switch the RUN/PROG key to the PROG position.

Section 2.2.5 Tonnage Monitor Restricted Items

The following table lists the PLC Interface restricted items name and function.

PLC INTERFACE RESTRICTED ITEMS

NAME

FUNCTION

PLC Screen 1 Sets

Change Settings on PLC Screen 1

PLC Screen 2 Sets

Change Settings on PLC Screen 2

PLC Screen 3 Sets

Change Settings on PLC Screen 3

PLC Screen 4 Sets

Change Settings on PLC Screen 4

Section 2.2.6 Access Control Operation

To gain access control the user must use one of two means or a combination of these two means. These
means are the RUN/PROG key or the user password system.

Section 2.2.6.1 RUN/PROG Key Switch Operation

The RUN/PROG key switch is located on the lower right side of the operator terminal. This is a two
position switch. The key is removable in the RUN position only. If the RUN/PROG key switch is
being used as a means to access the restricted items, the switch must be turned to the PROG position.
When the RUN/PROG key switch is switched to the PROG position, the press will Top Stop and