FEATURES

!

Selectable auto backlight

Selectable auto shut-off

Hold function

ZERO range ( 0% - 4% of full capacity)

TARE range ( 4% - 100% of full capacity)

Animal weighing mode

AnyCal calibration software

Selectable calibration units: kg or lb

RS232

!!

!

2.2 Application, conformity

!

2.2.1 Correct use of the weighing machine

!

The maximum allowable load of the weighing machine must never be exceeded, otherwise the weighing

machine may be damaged.

!

In using the weighing machine in combination with other appliances as well as with appliances produced

by other manufacturers, the appropriate regulations for the safe use of the relevant attachments and their

application in accordance with instructions must be observed.

!!

2.2.2 Conformity

!

The weighing machine has been manufactured and tested in accordance with the standards and

recommendations set out in the declaration of conformity.

!

The power adapter produced for the operation of the weighing machine and intended exclusively for this

application, complies with the appropriate electrical protection class.

!!

!

2.3 Data and parameters

!

2.3.1 Technical data

!

The following applies to Weigh Bar series

!

Power supply:

!

. Input: 110 or 230V AC (+/-15-20%); 50 to 60Hz

!

Power source

6 x AA Dry cells ( not included) or Adapter:12V DC / 150 mA

!

12