Installation, Continued, For built-in installation – Desa FDCFTN User Manual

Page 13: Extension cord

Advertising
background image

111244-01A

For more information, visit www.desatech.com

For more information, visit www.desatech.com

13

13

3
2
1

O

F
F

P

IL

OT

O

N

H

I

L

O

Red

Red

Fan Switch

(Auto/Off/On)

Blue

Blue

Thermostat

Switch

(N.O.)

Green

White

Green

White

On

110/115

V.A.C.

Blower

Motor

Black

Off

1

2

3

Auto

Figure 17 - Installing Blower Bracket Assembly

Figure 18 - Wiring Diagram For Blower Accessory Built-In
Installation

INSTALLATION

Continued

INSTALLATION

Installing Blower Accessory GA3450TA (Cont.)

For Built-In Installation

WARNING: A licensed electrician must connect the

wiring harness to electrical supply following all local
codes. Electrician must provide a clamp on the box cover
to secure the wiring. Wiring should be routed through the
bushing in the hole on the outer casing of fireplace.

1.

Install snap bushing from blower kit into one hole on rear of re-
mote/blower bracket (see Figure 17). The other hole is for a strain
relief clamp (not supplied) to secure incoming electrical supply.

2.

Follow steps 2 through 6 in Installing Blower Accessory, page 12.

3.

A licensed electrician must follow the wiring diagram to connect
incoming electrical supply to fan kit wiring harness (see Figure 18).

4.

Plug power cord to outlet receptacle (not provided) as shown in
Figure 17. Wind extra cable of power cord and tie up with plas-
tic wire strap (see Figure 17). Set cable bundle between the re-
mote/blower bracket and outer casing, away from the burner.

5.

Test to make sure blower is working properly.

6.

Reinstall upper louver beginning with bottom screws (see Fig-
ure 11, page 10) and close lower louver.

Blower Bracket
Assembly

Screw

Wire Harness

Plastic Wire
Strap

Wire
Harness

Switch
Plate

Switch

Blue

Red

Power Cord

Lower Louver Door

Black

Extension Cord

Use extension cord if needed. The cord must have a three-prong,
grounding plug and a three-hole receptacle. Make sure cord is in good
shape. It must be heavy enough to carry the current needed. An
undersized cord will cause a drop in line voltage. This will result in
loss of power and overheating. Use a No. 16 AWG cord for lengths
less than 50 feet.

Outlet Receptacle
(not included)

Remote/ Blower
Bracket

Clamp Connector
(not included)