CLEANING AND MAINTENANCE

Cleaning Burner Injector Holder and Pilot Air Inlet Hole (Cont.)

Log Set

Cabinet

WIRING DIAGRAM

Figure 50 - Injector Holder On Outlet Burner Tube

Burner
Tube

Injector Holder

Primary Air
Inlet Holes

5.

Blow air into the primary air holes on the injector holder.

6.

In case any large clumps of dust have now been pushed into
the burner repeat steps 3 and 4.

Clean the pilot assembly also. A yellow tip on the pilot flame
indicates dust and dirt in the pilot assembly. There is a small pilot
air inlet hole about two inches from where the pilot flame comes out
of the pilot assembly (see Figures 51 or 52 depending on model).
With the unit off, lightly blow air through the air inlet hole. You may
blow through a drinking straw if compressed air is not available.

Figure 51 - Pilot Inlet Air Hole
(Propane/LP Gas)

Pilot Assembly

Pilot Air Inlet Hole

Pilot Assembly

Pilot Air Inlet Hole

Figure 52 - Pilot Inlet Air Hole
(Natural Gas)

CLEANING AND
MAINTENANCE

Continued

LOG SET

• If you remove one-piece log set for cleaning, refer to Installing

Log Set and Screen, page 19, for placement instructions.

• Replace log set if broken or chipped (dime-sized or larger).

CABINET

Air Passageways

• Use a vacuum cleaner or pressurized air to clean.

Exterior

• Use a soft cloth dampened with a mild soap and water mixture.

Wipe the cabinet to remove dust.

WIRING DIAGRAM

(Remote-Ready Models Only)

Switch

Black

Auto

Off
On

Red

Red

White

Thermopile

Gas Control

TPTH

TH