Installation, Continued – Desa FDCFTN User Manual

Page 8

Advertising
background image

111244-01A

For more information, visit www.desatech.com

For more information, visit www.desatech.com

8

FIREPLACE CLEARANCES

WARNING: Maintain the minimum clearances

shown in Figure 6. If you can, provide greater clear-
ances from floor, ceiling, and joining wall.

NOTICE: If you install the fireplace in a bedroom
(Thermostat-Controlled Models only), some building
codes require that the fireplace/mantel system be
secured to (or within) a wall. You can position fire-
place in an optional cabinet or corner mantel. You can
also recess fireplace into the wall.

INSTALLATION

Continued

Use the dimensions shown for rough openings to create the easiest
installation (see Built-In Fireplace Installation, page 9).

CHECK GAS TYPE

Use the correct gas type (natural or propane/LP) for your unit. If
your gas supply is not correct, do not install fireplace. Call dealer
where you bought fireplace for proper type fireplace.

INSTALLATION ITEMS

Before installing fireplace, make sure you have the items listed
below.

• external regulator (supplied by installer, for propane/LP units only)
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• equipment shutoff valve *
• test gauge connection*
• ground joint union
• sediment trap
• tee joint
• pipe wrench

* A CSA design-certified equipment shutoff valve with 1/8" NPT
tap is an acceptable alternative to test gauge connection. Purchase
the optional CSA design-certified equipment shutoff valve from
your dealer. See Accessories, pages 36 and 37.

Note:

If desired, purchase a four-sided brass trim kit for built-in

installations. See Accessories, pages 36 and 37.

If your fireplace is to be used with an optional mantel, the
installation instructions included with your mantel shows an CSA
approved method of attaching the fireplace/mantel system to a
wall.

IMPORTANT:

Only use optional cabinet or corner mantels

specified in this manual. Purchase the optional mantel from your
dealer (see Accessories, pages 36 and 37).

If your fireplace is to be recessed into the wall, see Built-In Fireplace
Installation
on page 9 to secure your fireplace into the wall.

CAUTION: If you install the fireplace in a home

garage
• fireplace pilot and burner must be at least 18

inches above floor.

• locate fireplace where moving vehicle will not hit it.

For convenience and efficiency, install fireplace

• where there is easy access for operation, inspection, and service

• in coldest part of room

An optional blower kit is available from your dealer. See Accesso-
ries
, pages 36 and 37. If planning to use blower, follow instructions
provided with blower for power source.

Minimum Clearances For Side Combustible
Material, Side Wall, and Ceiling

A. Clearances from the side of the fireplace cabinet to any com-

bustible material and wall should follow diagram in Figure 6.

Example:

The face of a mantel, bookshelf, etc. is made of

combustible material and protrudes 3

1

/

2

" from the wall. This

combustible material must be 4" from the side of the fireplace
opening (see Figure 6).

B. Clearances from the top of the fireplace opening to the ceiling

should not be less than 36 inches.

C. For mantel clearances, see Figure 10 on page 10.

Figure 6 - Minimum Clearance for Combustible to Wall

*Minimum 16 inches from Side Wall

*

Example

INSTALLATION

Check Gas Type
Installation Items
Fireplace Clearances

MINIMUM CLEARANCE TO

COMBUSTIBLE MATERIALS

Top

Left and

Bottom

Right Sides

and Rear

36"

6"

0"

Advertising
This manual is related to the following products: