Owner’s manual, Operating appliance, Continued – Desa VVDA24R User Manual

Page 13

Advertising
background image

13

901272

OWNER’S MANUAL

O

F

F

PIL

OT

O

N

1.

STOP! Read the safety information,
page 12 column 3.

2.

Make sure manual shutoff valve is
fully open.

3.

If Using Optional Hand-Held Re-
mote or Wall Switch:

Set switch to

OFF position.

4.

Press in and turn control knob clock-
wise

to the OFF position.

5.

Wait five (5) minutes to clear out any
gas. Then smell for gas, including
near the floor. If you smell gas,
STOP! Follow “B” in the safety in-
formation, page 12 column 3. If you
don’t smell gas, go to the next step.

6.

Press in and turn control knob coun-
terclockwise

to the PILOT

position. Press in control knob for
five (5) seconds (see Figure 23).

Note:

You may be running this log

set for the first time after hooking up
to gas supply. If so, the control knob
may need to be pressed in for 30 sec-
onds or more. This will allow air to
bleed from the gas system.

7.

With control knob pressed in, press
and release ignitor button. This will
light pilot. If needed, keep pressing
ignitor button until pilot lights.

Note:

If pilot does not stay lit, contact a

qualified service person or gas supplier
for repairs. Until repairs are made, light
pilot with match. To light pilot with
match, see Manual Lighting Procedure
.

Figure 23 - Control Knob and Ignitor But-
ton Location (Shown as Supplied, No
Control Options)

WARNING: Burner will come

on automatically within one minute
when the selector switch is in the
ON position after the pilot is lit.

Control
Knob

Igniter
Button

Pilot

Ther-
mopile

Figure 24 - Thermopile and Pilot

LIGHTING

INSTRUCTIONS

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Appliance

1.

Slightly push in and turn control
knob clockwise

to the OFF

position.

Shutting Off Burner Only (pilot
stays lit)

You may shut off the burner and keep the
pilot lit by doing one of the following:

1.

Slightly push in and turn control
knob clockwise

to the PI-

LOT position.

2.

If Using Optional Hand-Held Re-
mote or Wall Switch:

Set switch to

OFF position.

MANUAL LIGHTING

PROCEDURE

1.

Follow steps 1 through 6 under Light-
ing Instructions
.

2.

Depress control knob and light pilot
with match.

3.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob. Now
follow steps 9 through 10.

OPERATING
APPLIANCE

Continued

8.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.
• If control knob does not pop out when

released, contact a qualified service
person or gas supplier for repairs.

Note:

If pilot goes out, repeat steps

4 through 8.

9.

Slightly push in and turn control
knob counterclockwise

to

the ON position.

10.

If Using Optional Hand-Held Re-
mote or Wall Switch:

Wait one

minute and switch selector switch to
the ON position to light burner.

Continued

Advertising
This manual is related to the following products: