Owner’s manual, Installation – Desa VVDA24R User Manual

Page 7

Advertising
background image

7

901272

OWNER’S MANUAL

INSTALLATION

WARNING: Before installing

in a solid fuel burning fireplace,
the chimney flue and firebox must
be cleaned of soot, creosote,
ashes and loose paint by a quali-
fied chimney cleaner. Creosote
will ignite if highly heated. A dirty
chimney flue may create and dis-
tribute soot within the house. In-
spect chimney flue for damage.

NOTICE: Installation, service, and
repair of this appliance must be
performed by a qualified installer,
service agency, company or gas
supplier experienced with this
type of gas appliance. Only fac-
tory authorized components listed
in these instructions may be used
in accordance with the
manufacturer’s instructions and
all codes and requirements of the
authority having jurisdiction. Any
modifications to this kit, or use of
unauthorized components or ac-
cessory items will void the
manufacturer’s warranty, and may
result in a hazardous condition.

CHECK GAS TYPE

Use only natural gas. If your gas supply is not
natural gas, you must convert the appliance
to propane/LP. Follow the instructions on
page 10.

If the fireplace does not have a gas supply
shut-off valve, one must be installed.

CAUTION: Do not remove

the metal data plates attached
to the burner pan. The data plates
contain important warranty in-
formation.

FLUE OPENING
SPECIFICATIONS

Note:

This vented appliance must be in-

stalled only in a solid-fuel burning fireplace
with a working flue and constructed of non-
combustible material.

The charts in Figure 4 indicate technical
information regarding the installation of
your gas log set. Please make sure that all of
the specifications shown are applicable be-
fore installation is attempted.

The fireplace must include a working flue
and venting system with the minimum open-
ings shown in the Figure 4.

Continued

MODEL

DESCRIPTION

VVSA18R

18" Single Burner

50,000

40,000

VVSA24R

24" Single Burner

60,000

50,000

VVDA18R

18" Dual Burner

55,000

45,000

VVDA24R

24" Dual Burner

65,000

55,000

VVDA30R

30" Dual Burner

70,000

60,000

Btu Input

Natural Gas

Btu Input

Propane/LP Gas

The minimum vent opening on all models is 8" in diameter.

MINIMUM FIREBOX SIZES

LOG

FRONT

BACK

SIZE

WIDTH WIDTH*

DEPTH HEIGHT

18"

34"

16"

14"

18"

24"

35

3

/

4

"

17"

15

1

/

2

"

18"

30"

42"

27"

18"

18"

*At depth indicated

Figure 4 - Technical Information Charts

VENTING SPECIFICATIONS
FOR INSTALLATION

The fireplace chimney flue and vent must be
drafting properly. To check the vent for proper
drafting: Light a tightly rolled newspaper on
one end and place it at the inside front edge of
the fireplace. Observe the smoke and be sure
the vent is properly drawing it up the chim-
ney. If the smoke spills out into the room,
extinguish the flame and remove any ob-
struction until proper venting is achieved.

The chimney flue must remain open a mini-
mum of 3" at all times during the operation
of this log set (see Figure 5, page 8).

BURNER ORIFICE

LOG

NATURAL

PROPANE/LP

SIZE

IN.

NUM.

COLOR

IN.

NUM.

COLOR

18"

.129

30

Green

.073

49

Red

24"

.141

28

Yellow

.086

44

Orange

30"

.157

22

Yellow/Blue

.089

43

Black

FUEL PRESSURE

SPECIFICATIONS (W.C.)

Inlet

Manifold*

NG

5.5"-10.5"

3.5"

LP

11"-13"

10"

* ± .2"