d. Session Options page

On the Session Options page, under Input Signal Levels, select either ‘Video (16-235)’ (to
support the Panasonic Limited range) or ‘PC (0-255)’ (to support the Panasonic Full
range).

2. Display Pre-Test section
In the ‘Display Pre-Test’ section of the Color Cube workflow, you can measure the performance of a
display before you calibrate it, on the Gamma & ColorChecker page and on the Advanced Linearity page.
Because t

here are no Brightness, Contrast or Luminance controls available in the

Panasonic User 1

through User 3

operating modes, however, you will not optimize any monitor picture controls

before performing the 3D LUT calibration.

3. Display Optimization section
Because there are no picture controls available in the Panasonic User 1 through User 3 operating modes,
skip the Display Optimization section of the workflow. Skip directly to the 3D Cube LUT page.

4. Display Calibration section
In the Display Calibration section of the Color Cube workflow, there are provisions for calibrating both a
1D RGB LUT (1D Ramp LUT page) and a 3D cube LUT (3D Cube LUT page). When we are calibrating a
Panasonic monitor with a 3D LUT, we will skip the 1D Ramp LUT page (1D RGB LUT) and use only the 3D
Cube LUT
page.

a. 1D Ramp LUT page
Skip over this page when creating a 3D LUT file for a Panasonic monitor, since we do not need to
create a 1D LUT.

b. 3D Cube LUT page

1. On the 3D Cube LUT page, click the AutoCal (rotating arrows) button at the right end of

the meter action buttons. The AutoCal Setup dialog then appears (see below).