Spectrum Controls 1746sc-NI8u User Manual
Page 39
Advertising

Chapter 3: Things To Consider Before Using Your Module
27
Figure 3.2 Signal attenuation with 10 Hz input filter
0
-20
-40
-60
-80
-100
-120
-140
-160
-180
-200
0
10
20
30
40
50
60 Hz
-3 dB
2.62 Hz
Amplitude (in dB)
Signal Frequency
Figure 3.3 Signal attenuation with 50 Hz input filter
0
-20
-40
-60
-80
-100
-120
-140
-160
-180
-200
0
50
100
150
200
250
300 Hz
-3 dB
13.1 Hz
Amplitude (in dB)
Signal Frequency
Advertising