Diode Test

Test Current

Over Load Protection

1.5mA MAX

250 V DC or AC RMS

Continuity Buzzer

Test Voltage

Threshold

Over Load Protection

3V

<35

250 V DC or AC RMS

Non-Contact Voltage (NCV)

Detection Range: 24VAC and above

Temperature (K-Type thermocouple)

Range

Res. Accuracy

-30ºF to 1000ºF 1ºF

+(2ºF) 32.0ºF to 120ºF
+ (1%+2ºF) -3ºF to 749ºF
+ (2%+1.5ºF) 750ºF to 1000ºF
+ (2%+4ºF) -40ºF to -4ºF

Overload Protection: 60VDC or 30VAC RMS

**Celsius version of the 275 is available

11

10

Capacitance

Range

Res.

Accuracy

11nF

0.001nF

±(3% of reading +5 digits)

110nF

0.01nF

1.1uF

0.0001uF

Overload Protection:

11

µF

0.001

µF

500VDC or AC RMS

110

µF

0.01

µF

1.1mF

0.0001mF

11mF

0.001mF

110mF

0.01mF

±(7% of reading +5 digits)

nF= nanofarad,

µF= microfarad, mF= millifarad

General

Max Voltage between any

600V

input and ground

Fuse Protection (

µµA range) 0.5A/600V

Display Type

4000 Count 41 seg. bargraph

Operating Temperature

32ºF to 104ºF (0ºC to 40ºC)

Storage Temperature

14ºF to 122ºF (-10ºC to 50ºC)

Relative Humidity

80% non-condensing

Power Supply

9V (MN1604)

Battery Life

80 hrs. typical

Size (H x L x W)

32.5mm x 255mm x 65mm

(1.3in x 10in x 2.5in)

Weight

363g (0.8lbs)

Warning:

Use only correct type and overvoltage
category rated test leads. Remove the
temperature probe when using the test
leads or amp clamp.

Warning:

Use only correct type and overvoltage
category rated test leads. Remove the
temperature probe when using the test
leads or amp clamp.