Test Products International 275 User Manual

Page 14

Advertising
background image

Measuring AC Voltage

WARNING!

Do not attempt to make a voltage measurement of more than

600V or of a voltage level that is unknown. Make sure the tem-
perature probe is NOT plugged in during this test.

Instrument set-up:

FUNC.

BLACK RED

MIN

MAX

TEST LEAD TEST LEAD

READING

READING

COM

V/

0.1mV

600V

Measurement Procedure:

1.

Disconnect power to circuit to be measured.

2.

Plug black test lead into the COM input jack.

3

Plug red test lead into the V/

input jack.

4.

Set rotary switch to the V range.

5.

Connect test leads to circuit to be measured.

6.

Reconnect power to circuit to be measured.

7.

Read the voltage on the 275.

Optional Modes

(See Other Features Section)

D-H:

Freezes the reading on the LCD.

MAX/MIN:

Records minimum and maximum measurements.

P-H:

Displays peak voltage.

2. Step by Step Procedures:

Measuring DC Voltage

WARNING!

Do not attempt to make a voltage measurement of more
than 600V or of a voltage level that is unknown. Make sure
the temperature probe is NOT plugged in during this test.

Instrument set-up:

FUNC.

BLACK RED

MIN

MAXI

TEST LEAD TEST LEAD

READING

READING

COM

V/

0.1mV

600V

Measurement Procedure:

1.

Disconnect power to circuit to be measured.

2.

Plug black test lead into the COM input jack.

3

Plug red test lead into the V/

input jack.

4.

Set rotary switch to the V range.

5.

Connect test leads to circuit to be measured.

6.

Reconnect power to circuit to be measured.

7.

Read the voltage on the 275.

Optional Modes

(See Other Features Section)

D-H:

Freezes the reading on the LCD.

MAX/MIN:

Records minimum a.

P-H:

Displays peak voltage.