G. trouble shooting – Test Products International 275 User Manual

Page 35

Advertising
background image

35

34

G. Trouble Shooting

Problem

Probable Causes

Does not power up

•

Dead or defective battery

•

Broken wire from battery
snap to PCB

Won’t display DC

•

Open fuse

microamp readings

• Open test lead
•

Improperly connected to
circuit under test

All functions except

•

Very weak battery that will

ohms read high

not turn on the low battery
indicator on the LCD

AC Volts do not read

•

Very weak battery that will
not turn on the low battery
indicator on the LCD

Non-Contact Voltage

•

The non-contact voltage feature

does not work

works best when used to test a
single wire. Make sure the arrow
on the jaw is pointed at the wire.

The meter beeps when

•

This is a reminder to remove the

set on TEMP

test leads and insert the temper-
ature probe. If a probe is insert-
ed, this is an indication the probe
is open.

AC Amps does not read

•

Make sure the jaw is clamped
around a single wire and the
device connected to the wire is
turned on.

Application Notes

(Temperature Differential)

When measuring temperature there may be applica-

tions when knowing the differential between two mea-

surements is required. This can be accompished by

following these steps.
•

Remove the test leads from the input jacks. Insert

the K-type thermocouple probe into the input jack
on the 275. Set the 275 to the desired TEMP
function.

•

Touch the temperature probe sensor to the device

under test (T1).

•

When the reading stabilizes, press the REL but-

ton. The display will read “0” and T1 will be
stored as the reference value that the next mea-
surement will be made relative to.

•

Touch the temperature probe sensor to the device

under test (T2).

•

The 275 will display the differential temperature

T2-T1.

Advertising