airFiber® AF-5/AF-5U Quick Start Guide

3.

Master

Visually aim the Master at the Slave. To adjust the

Master's position:

a. Rotate the airFiber radio on the pole to align the azimuth.
b. Use the hex nut on the Elevation Rod to adjust the elevation.

Note:

Do NOT make simultaneous adjustments on the

Master and Slave.

4.

Slave

Visually aim the Slave at the Master. To adjust the Slave's

position:

a. Rotate the airFiber radio on the pole to align the azimuth.
b. Use the hex nut on the Elevation Rod to adjust the elevation.

5. Check to see if a link is established. Ensure that the Link Status

LED is solidly lit green and the Remote and Local LED Displays of

the Slave are displaying signal levels.