32

Chapter 1: Tools

airFiber

®

AF-5X User Guide

Ubiquiti Networks, Inc.

Launch airView

Click Launch airView to download the

Java Network Launch Protocol (jnlp) file and complete
the launch of airView.

Main View

Device

Displays the device name, MAC (Media Access

Control) address, and IP address of the device running
airView.

Total RF Frames

Displays the total number of Radio

Frequency (RF) frames gathered since the start of the
airView session or since the Reset All Data button was last
clicked.

FPS

Displays the total number of frames per second (FPS)

gathered since the start of the airView session or since
the Reset All Data button was last clicked. The wider the
interval amplitude, the fewer the FPS will be gathered.

Reset All Data

Click to reset all gathered data. Use this

option to analyze the spectrum for another location or
address.

File Menu

Click Exit to end the airView session.

View Menu

Enable Chart Panel 1 (top)

Displays the Waterfall or

Channel Usage chart in Chart Panel 1, depending on
which option you have selected in Preferences. This
time-based graph shows the aggregate energy collected
or channel usage for each frequency since the start of the
airView session.

Enable Chart Panel 2 (middle)

Displays the Waveform

chart in Chart Panel 2. This time-based graph shows the RF
signature of the noise environment since the start of the
airView session. The energy color designates its amplitude.
Cooler colors represent lower energy levels (with blue
representing the lowest levels) in that frequency bin, and
warmer colors (yellow, orange, or red) represent higher
energy levels in that frequency bin.

Enable Chart Panel 3 (bottom)

Displays the Real-time

chart (traditional spectrum analyzer) in Chart Panel 3.
Energy (in dBm) is shown in real time as a function of
frequency.

Note:

Energy is the power ratio in decibels (dB) of

the measured power referenced to one milliwatt
(mW).

Clear All Markers

Resets all previously assigned

markers. Markers are assigned by clicking a point, which
corresponds with a frequency on the Real-time chart.

Preferences

Changes airView settings, such as enabling

or disabling charts and traces, or specifying the frequency
interval.

Preferences

Select View > Preferences to display the Preferences -
airView Spectrum Analyzer
window.