Introduction, Safety information, Specifications – UVP 81-0357-01 PCR Hoods User Manual

Page 2: Standard uv (uv1 and uv2) pcr models

Advertising
background image

PCR Workstations and Cabinets

Page 2

Introduction

The UV1 and UV2 PCR Hoods create an ideal environment for preparing PCR and other samples
by reducing the chance of contamination. The built-in high intensity shortwave (254nm) UV
provides a source for inactivation of DNA between experiments. Additional contamination control is
provided by the specially-coated stainless steel and aluminum design that maintains antimicrobial
efficacy. The surface resists growth of destructive bacteria, molds and fungi. The Makrolon

®

panel

assembly blocks UV below 400nm.

In addition to the UV1/UV2 PCR Hood features, HEPA/UV3 PCR Hoods provide additional
protection by blowing filtered air, treated by the HEPA/UV system, into the PCR chamber.

The UV/Air Circulator, included as standard on UV2 and HEPA/UV3 PCR Hoods and optional on
the UV1 PCR Workstation (95-0367-xx only), eliminates amplicons of DNA or genomic DNA from a
previously-dispensed experiment. For ordering information, refer to the “Maintenance and
Replacement Parts/Accessories” section.

Safety Information

The PCR Hoods are designed with functionality, reliability and safety in mind. The Hoods provide
shortwave (254nm) UV which is a powerful source of UV radiation that will cause damage to
unprotected eyes and skin. Before operating, ensure that all personnel are properly protected and that
the instructions for the use of this equipment are followed. A safety shut-off switch automatically turns
off the UV light when the door is open, protecting users from UV exposure. In addition, the Makrolon

®

panels are specially formulated to block UV wavelengths below 400nm.

Disconnect the power supply before assembling or servicing the PCR Hoods.

Specifications

STANDARD UV (UV1 and UV2) PCR MODELS

UV1 PCR Cabinet

UV2 PCR Cabinet

UV1 PCR Workstation

UV2 PCR Workstation

95-0437-01 115V
95-0437-02 230V UK
95-0437-04 230V Euro
95-0437-03 100V

95-0436-01 115V
95-0436-02 230V UK
95-0436-04 230V Euro
95-0436-03 100V

95-0367-01 115V
95-0367-02 230V UK
95-0367-04 230V Euro
95-0367-03 100V

95-0439-01 115V
95-0439-02 230V UK
95-0439-04 230V Euro
95-0439-03 100V

Light Sources:
254nm 8-watt UV:

 Chamber

White 8-watt

 Chamber

Light Sources:
254nm 8-watt UV:

 Chamber
 UV/air circulator

White 8-watt:

 Chamber

Light Sources:
254nm 25-watt UV:

 Chamber

White 15-watt:

 Chamber

Light Sources:
254nm 25-watt UV:

 Chamber

254nm 8-watt UV:

 UV/air circulator

White 15-watt:

 Chamber

Features include:
Two power outlets
Two small shelves
UV Timer
Antimicrobial coated

stainless steel (work
surface) & aluminum

Makrolon

®

panels

block below 400nm

Features include:
Two power outlets
Two small shelves
UV Timer
Antimicrobial coated

stainless steel (work
surface) & aluminum

Makrolon

®

panels block

below 400nm

UV/Air Circulator

Features include:
Four power outlets
Two shelves
UV Timer
Antimicrobial coated

stainless steel (work
surface) & aluminum

Makrolon

®

panels block

below 400nm

Optional: UV/Air Circulator

Features include:
Four power outlets
Two shelves
UV Timer
Antimicrobial coated

stainless steel (work
surface) & aluminum

Makrolon

®

panels block

below 400nm

UV/Air Circulator

Dimensions:
Exterior: 28.7H x 21.4W
x 24D in.
(729 x 544 x 610 mm)
Interior: 19.7W x 21.4D
in. (500 x 544 mm)

Dimensions:
Exterior: 28.7H x 21.4W
x 24D in.
(729 x 544 x 610 mm)
Interior: 19.7W x 21.4D
in. (500 x 544 mm)

Dimensions:
Exterior: 28.7H x 29W x
24D in. (729 x 737 x 610
mm)
Interior: 27.8W x 21.4D
in. (706 x 544 mm)

Dimensions:
Exterior: 28.7H x 29W x
24D in. (729 x 737 x
610 mm)
Interior: 27.8W x 21.4D
in. (706 x 544 mm)

Advertising