Troubleshooting – Toro ECXTRA INDOOR User Manual

Page 40

Advertising
background image



If you are having a problem with the timer, check the following symptoms, possible causes and remedies.

If the problem cannot be resolved, or you would like assistance with any Toro irrigation product, call our toll-free

Toro Help Line

at 1-800-367-8676, Monday through Friday, 7:30 a.m. – 4:00 p.m. (Pacific Time).

Troubleshooting

Possible Cause

Main power is disconnected.

Watering programs have overlapping

schedules.

Faulty control valve wire connections.

Automatic Circuit Protection has

disabled the zone.

Zone run time is turned Off.

Control valve problem.

More than one start time on the

program.

Season Adjust setting greater than

100%.

Remedy

Check the transformer connections

(indoor model) or circuit breaker

service panel (outdoor model).

Shorten zone run times (p. 28) and/or

space start times farther apart (p. 27).

Check the wire connections at the

control valve and timer.

Check for faulty valve solenoid and

replace if necessary.

Enter a zone run time (p. 28)

Inspect, clean and/or repair valve

as needed.

Remove additional program start

times (p. 27).

Review Season Adjust factor (p. 34).

Symptom

The display is blank and the
timer does not operate.

Watering programs start at
unscheduled times.

Watering zone does not turn on.

Watering zone does not turn off.

An Program restarts unexpectedly
after the completion of an
automatic operation.

Advertising
This manual is related to the following products: