Toro ECXTRA INDOOR User Manual

Page 43

Advertising
background image

Season Adjust
Season Adjust enables the run time of all zones to be

adjusted up or down simultaneously in 10% increments

from 10% to 200%. Any increase over 100% will first

increase the time by the adjusted percentage, then split

the time in half and run the watering cycle twice.
Sensor Connection Terminals
Snap-in terminals for rain sensor wiring connections.
Start Time
A start time is the time selected to begin a watering pro-

gram cycle. Each program (A, B and C) can be assigned

with up to four different start times
Terminal Block
Connection point for 115 VAC input power in the

Outdoor model timer.
Time Pod
Portable electronic device used to transfer ECXTRA

watering schedule information from the PC-based

program to the ECXTRA timer.
Transformer
See “Power Supply.”
Valve Common Wire
One solenoid wire connection from each sprinkler valve

connected to the timer’s “COM” terminal.

Watering Program
A watering program (or schedule) is the information

stored in the timer memory that determines when an

automatic watering cycle will occur and how long each

zone will water. The timer requires three basic instruc-

tions to operate automatically:

• Which days to water – called watering days.

• What time to start the watering program cycle –

called program start time.

• How long each zone will water during the cycle –

called zone run time
Watering Day
The day(s) of the week selected to water.
Watering Program Cycle
The ECXTRA is designed to operate one sprinkler zone at

a time. When a scheduled program start time occurs, the

lowest zone number (assigned to the program) starts and

waters for its set run time duration. When the zone times

out, the next zone in numeric sequence starts and runs for

its set run time duration. The watering cycle continues in this

manner until all assigned stations have operated.
Zone
Each valve controls a specific group of sprinklers called

a watering zone. The zones are generally laid out and

installed according to the various portions of the land-

scape to be watered, such as a lawn or flower bed. Each

valve is connected to a numbered terminal within the

timer, identifying it as Zone 1, Zone 2, etc.
Zone Run Time

The length of time a zone will operate during a watering

cycle. Run time can be set from 1 minute to 4 hours.



Advertising