Battery saver ("sleep mode"), Terminals, Rotary switch positions – Fluke 179 User Manual

Page 6

Advertising
background image

Models 175, 177 & 179
Users Manual

2

Battery Saver ("Sleep Mode")

The Meter enters the "Sleep mode" and blanks the display if there

is no function change or button press for 20 minutes. To disable

the Sleep mode, hold down the YELLOW button while turning the

Meter on. The Sleep mode is always disabled in the MIN MAX

AVG mode and the AutoHOLD mode.

Terminals

.

FUSED

V

1

2

3

4

AIK01F.EPS

Item Description

1

Input terminal for AC and DC milliamp measurements to

400 mA and frequency measurements.

2

Input terminal for AC and DC current measurements to

10 A and frequency measurements.

3

Input terminal for voltage, continuity, resistance, diode,

capacitance, frequency, and temperature (Model 179

only) measurements.

4

Common (return) terminal for all measurements.

Rotary Switch Positions

Switch

Position

Measurement Function

K

Hz

AC voltage from 30.0 mV to 1000 V.
Frequency from 2 Hz to 99.99 kHz.

L

Hz

DC voltage 1 mV to 1000 V.
Frequency from 2 Hz to 99.99 kHz.

mL

T

DC mV 0.1 mV to 600 mV.
Temperature

40

°

C to

+

400

°

C

40

°

F to

+

752

°

F

e

E

Ohms from 0.1

Ω

to 50 M

Ω

.

Farads from 1 nF to 9999

μ

F.

R

G

Beeper turns on at

<

25

Ω

and turns off at

>

250

Ω

.

Diode test. Displays OL above 2.4 V.

FB

mA

AC mA from 3.00 mA to 400 mA
DC mA from 0.01 mA to 400 mA

Hz

Frequency of AC mA 2 Hz to 30 kHz.

F

AC A from 0.300 A to 10 A

B

A

DC A from 0.001 A to 10 A

>

10.00 display flashes.

>

20 A, OL is displayed.

Hz

Frequency of AC A 2 Hz to 30 kHz.

Note: AC voltage and current AC-coupled, true RMS, up to 1 kHz.