Maintenance, Introduction, General maintenance – Fluke 189 User Manual

Page 79: Testing the fuses, Chapter 6

Advertising
background image

6-1

Chapter 6

Maintenance

Introduction

This chapter describes basic operator maintenance. For
calibration and performance test information, order the
187 & 189 Service Manual, PN 1584337.

General Maintenance

Periodically wipe the case with a damp cloth and mild
detergent. Do not use abrasives or solvents.

Dirt or moisture in the terminals can affect readings and
can falsely activate the Input Alert feature. Clean the
terminals as follows:

1. Turn the meter off and remove all test leads.

2. Shake out any dirt that may be in the terminals.

3. Soak a new swab with alcohol. Work the swab around

in each terminal.

Testing the Fuses

Before measuring current, test the appropriate fuse as
shown in Figure 6-1. If the tests give readings other than
those shown, have the meter serviced.

W

Warning

To avoid electrical shock or personal injury,
remove the test leads and any input signals
before replacing the battery or fuses. To
prevent damage or injury, install ONLY
specified replacement fuses with the
amperage, voltage, and speed ratings shown
in Chapter 7.