Frame packing, See par. 4.2.5, Refer to par. 4.2.5 for rx t – Datalogic Scanning DL Cordless Card DLCC User Manual

Page 38: 5 frame packing

Advertising
background image

DL CORDLESS CARD™

4

4.2.5 Frame

Packing


This parameter defines the format of the frame to be transmitted between DLCC and
the Host.
The frame received by DLCC may contain a maximum of 238 characters. All
characters not included within this number will be transmitted from the Host in a new
frame.

Frame from Host to DLCC

FRAME



Address Address

Delimiter

MESSAGE


The Address field has different meanings depending on if the FRAME is sent as a 2
way answer to an RF device, or if it is a new message that the DLCC Client sends to
a destination device. See par. 4.3.2 for details.

Frame from DLCC to Host

FRAME



*Header Address Address

Delimiter

MESSAGE



*Header **Time-Stamp **Time-Stamp-Del **Code Id Code Len

DATA

Terminator


* There is only one header whose position can be defined through the related

parameter (see par. 4.3.1).

** These are optional fields which can be configured depending on the type of RF

device used.


The Address field has different meanings depending on if the FRAME is a 2 way
answer to a previous 2 way transaction initiated by a DLCC Client, or if it is a new
message that an RF device sends to the DLCC Server. See par. 4.3.2 for details.

24

Advertising