DL CORDLESS CARD™

4

This string is always transmitted in a single frame preceding the one containing

the configuration command, as shown in the following examples:

Example

1

Sending the $+$![CR] command to transmit the card software release:

1

st

Frame = #+++PROG_REQ+++#

2

nd

Frame = $![CR]


Example

2

Sending the $+ML0$-[CR] command to set the default frame packing

configuration:

1

st

Frame = #+++PROG_REQ+++#

2

nd

Frame = ML0$-[CR]



4.3 DATA

FORMAT


4.3.1 Header/Terminator

Selection


The header/terminator selection is not effected by restore default command.

Header Position

This parameter defines the header position within the frame to be transmitted from
DLCC to the Host. The header can be positioned in either the first field of the frame
or in the field preceding the message:

FRAME



HEADER

Address Address

Delimiter

MESSAGE



HEADER

Time-Stamp

Time-Stamp-Del

Code Id

Code Len

DATA

Terminator




The Address field has different meanings depending on if the FRAME is a 2 way
answer to a previous 2 way transaction initiated by a DLCC Client, or if it is a new
message that an RF device sends to the DLCC Server. See par. 4.3.2 for details.