Operation, Electric fireplace manual control – Dimplex DF3015 User Manual
Page 7
 
CAUTION
Clearance for air circulation beneath the fireplace insert is provided by three rubber feet.
DO NOT INSTALL THE FIREPLACE INSERT DIRECTLY ON CARPET OR SIMILAR 
SURFACES WHICH MAY RESTRICT AIR CIRCULATION. If installing the fireplace in a 
carpeted area, place a one-piece, solid, flat surface under the fireplace insert. Ensure that all 
three of the insert’s feet rest securely on this surface. 
OPERATION
ELECTRIC FIREPLACE MANUAL CONTROL
The manual controls for the fireplace are located in the lower right hand corner.
A. Main On/Off Switch 
Supplies power to the 3 position manual control switch. 
B. 3 Position Manual Control Switch
Remote (right position): The unit is operated with the remote control. 
Flame (center position): The flame effect is turned ON. 
Flame & Heat (left position): The flame effect and heater are turned ON simultaneously. 
When the manual control is in the Flame & Heat position the heater does not run on the 
remote operated thermostat. 
NOTE 
When the manual control switch is in the Flame and Flame & Heat positions, the fireplace 
unit will not operate with the remote control. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
FIGURE 2
Initialization
Button
3 Position
Manual 
Control
Main
On/Off 
Switch 
5