Remote control functions – Dimplex DF3015 User Manual
Page 9
 
FREQUENCY INTERFERENCE 
If the fireplace does not respond properly to the remote control, the remote operating 
frequency may have to be reset. The remote control can send another frequency code to the 
circuit board to eliminate interference. 
1. Simultaneously press the “SLEEP TIMER DOWN” button and the “PURIFIRE LOW
SPEED” button on the remote control.
2. “COD” will appear in place of the sleep timer digits. 
3. Release the “SLEEP TIMER DOWN” button and the “PURIFIRE LOW SPEED” button. 
4. Press the initialization button on the unit. 
5. press the button on the remote. 
 Your remote will now have a different frequency communicating with the fireplace. 
 
REMOTE CONTROL FUNCTIONS
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
FLAME/HEAT ON/OFF BUTTON 
Press the “Flame/Heat On/Off “button to turn the Flame/Heat function ON. When the “Set 
Temperature” is higher then the “Room Temperature” the heat will come on. To turn the 
heat off, lower the “Set Temperature” so that it’s setting is lower then the “Room 
Temperature”. The default temperature setting is 72°F (22°C). 
 
NOTE 
When using the remote control the heater runs on a thermostat. Press the “Temperature Up” 
or “Temperature Down” button to adjust the set temperature. Once the desired set 
temperature is reached the heater will turn OFF. The heater will cycle ON and OFF to 
maintain the desired set temperature. 
 
 
 
 
 
FIGURE 5
7
Temperature Up
Temperature 
Down 
Dimmer 
Down 
Dimmer Up
Flame Speed 
Down 
Flame Speed Up
Sleep Timer 
Down 
Sleep Timer Up
Purifire Low 
Speed 
Purifire High Speed
Flame & Heat 
On / Off 
Purifire On / Off
Batteries
Child Lock
Purifire
Room Temperature
Set Temperature
Dimmer
Flame Speed Control
Sleep Timer