1 mttf >= 10 years, 2 mttf >= 57 years, Mttf >= 10 years – Pilz PMCprimo DriveP.01/AA0/4/0/0/208-480VAC User Manual

Page 89: Mttf >= 57 years

Advertising
background image

Technical details

Operating Manual PMCprotego S1­2(­C)
1002528­EN­02

89

9.1.1.1

MTTF >= 10 years

Operating
mode

EN ISO
13849­1:
2008

PL

EN ISO
13849­1:
2008

Category

EN IEC
62061

SIL CL

EN IEC
62061

PFH

D

 [1/h]

IEC 61511

SIL

IEC 61511

PFD

EN ISO
13849­1:
2008

T

M

 [year]

Safe actu­
ator with
motor en­
coder, MTTF
≥ 10 years

PL d

Cat. 3

SIL CL 2

1,29E­07

SIL 2

6,09E­04

20

This operating mode requires a motor encoder with MTTF ≥ 10 years.

The motor encoder is already included in the characteristic data, so no more calculations
need to be performed for the "Safe Actuator" subsystem.

Subsystem

Safe actuator

PMCprotego D
PMCprotego S1
Motor encoder with MTTF ³ 10 years

The safety­related characteristic data is valid for all safety functions.

All the units used within a safety function must be considered when calculating the safety
characteristic data.

9.1.1.2

MTTF >= 57 years

Operating
mode

EN ISO
13849­1:
2008

PL

EN ISO
13849­1:
2008

Category

EN IEC
62061

SIL CL

EN IEC
62061

PFH

D

 [1/h]

IEC 61511

SIL

IEC 61511

PFD

EN ISO
13849­1:
2008

T

M

 [year]

Safe actu­
ator with
motor en­
coder, MTTF
≥ 57 years

PL e

Cat. 4

SIL CL 3

2,65E­08

SIL 3

4,94E­04

20

The characteristic data is valid when using a motor encoder with an MTTF ≥ 57 years.

The motor encoder is already included in the characteristic data, so no more calculations
need to be performed for the "Safe Actuator" subsystem.

Subsystem

Safe actuator

PMCprotego D
PMCprotego S1
Motor encoder with MTTF ³ 57 years