Pilz PSS SB HYD, Basic license User Manual
Programmable safety systems pss-range
Advertising
This manual is related to the following products:
- PSS SB HYD, General license PSS SB HYD, Copy license PSS SB HYD, Update license PSS SB TRA, Basic License PSS SB TRA, General license PSS SB TRA, Copy license PSS SB TRA, Update license PSS SB NOT, Basic license PSS SB NOT, general license PSS SB NOT, Copy license PSS SB NOT, Update license PSS SB FT, Basic license PSS SB FT, General license PSS SB FT, Copy license
Table of contents
Document Outline
- MBS Hydraulic Presses Version 3.2
- Preface
- Contents
- 1: Introduction
- 2: Overview
- 3: Safety
- 4: Intended Use
- System software
- Intended use of the standard function blocks
- SB051: Operating mode selector switch 1 from 8
- SB052: Operating mode selector switch 2 from 6
- SB059: Two-hand monitoring
- SB061: Emergency stop monitoring
- SB063: Emergency stop monitoring
- SB064: Safety gate monitoring
- SB065: Feedback loop monitoring
- SB066: Safety gate monitoring
- SB067: Feedback loop monitoring
- SB068: Monitoring ESPE/AOPDs with guarding and control function
- SB069: Monitoring ESPE/AOPDs with guarding function
- SB070: Initialisation of administration data block (DB015)
- SB071: Initialisation of administration data blocks (DB015/DB016/DB017)
- SB072: Temporary suspension of safety functions
- SB075: Controlling and monitoring safety gates with guard locking
- SB086: Overrun control on linear-driven presses
- SB087: Driving/monitoring the position of a single hydraulic valve (poppet and directional control valve)
- SB088: Driving/monitoring the position of a dual hydraulic valve (poppet and directional control valve)
- SB089: Sequential driving/monitoring the position of two hydraulic valves (poppet valve and directional control valves)
- SB092: Enable switch
- SB097: Monitoring muting lamps
- 5: MBS Basics
- 6: Standard Function Blocks
- Guidelines for selecting standard function blocks
- Emergency stop monitoring
- Safety gate monitoring
- Feedback loop monitoring
- Initialising the administration data bocks
- SB051: Operating mode selector switch, 1 from 8
- SB052: Operating mode selector switch, 2 from 6
- SB059: Two-hand monitoring
- SB061: Emergency stop monitoring, category 4
- SB063: Emergency stop monitoring, category 4
- SB064: Safety gate monitoring
- SB065: Feedback loop monitoring
- SB066: Safety gate monitoring
- SB067: Feedback loop monitoring
- SB068: Monitoring ESPE/AOPDs with guarding and control function
- SB069: Monitoring ESPE/AOPDs with guarding function
- SB070: Initialisation of administration data block DB015
- SB071: Initialisation of administration data blocks
- SB072: Temporary suspension of safety functions (ESPE/AOPD muting)
- SB075: Controlling and monitoring safety gates with guard locking
- SB086: Overrun control on linear-driven presses
- SB087: Driving/monitoring the position of a single hydraulic valve (poppet and directional control valve)
- SB088: Driving/monitoring the position of a dual hydraulic valve (poppet and directional control valve)
- SB089: Sequential driving/monitoring the position of two hydraulic valves (poppet and directional control valves)
- SB092: Enable switch
- SB097: Monitoring muting lamps
- 7: Link Blocks
- 8: Examples
- Applications and parameters of individual blocks
- Emergency stop monitoring with manual start (start-up and operation), category 4
- Emergency stop monitoring with automatic start-up, manual start (operation) and function test, category 4
- Feedback loop monitoring (shutdown with two contactors connected in series), category 4
- Feedback loop monitoring (shutdown with two main contactors connected in series and pulsed outputs), category 4
- Feedback loop monitoring (selective shutdown), category 4
- E-STOP monitoring with monitoring of feedback loop, category 4
- Safety gate monitoring with manual start and manual restart, category 2
- Safety gate monitoring with automatic start and manual restart, category 2
- Safety gate monitoring with manual start and manual restart, category 4
- Safety gate monitoring with automatic start and manual restart, category 4
- Safety gate monitoring with manual start and manual restart, category 4
- Safety sensors PSEN 2.1p and PSEN 2.1p-11 with block SB066 (ST_K4)
- ESPE/AOPD in guard mode with automatic function test (SB068)
- ESPE/AOPD in single break mode with cycle reset via a pulse at top dead centre (TDC)
- ESPE/AOPD in guard mode with automatic function test (SB069)
- Monitoring muting lamps
- Safety gate monitoring with guard locking, automatic start and manual restart, category 4
- 9: Appendix
- Assignment table: category and requirement class
- Standard function blocks: current versions
- Changes to the standard function blocks
- SB051: Operating mode selector switch, 1 from 8
- SB052: Operating mode selector switch, 2 from 6
- SB059: Two-hand monitoring
- SB061: Emergency stop monitoring
- SB063: Emergency stop monitoring
- SB064: Safety gate monitoring
- SB065: Feedback loop monitoring (RFK)
- SB066: Safety gate monitoring
- SB067: Feedback loop monitoring (RFK)
- SB068: Monitoring ESPE/AOPDs with guarding function
- SB069: Monitoring ESPE/AOPDs with guarding function
- SB070: Initialisation of administration data block (DB015)
- SB071: Initialisation of administration data blocks (DB015/DB016/DB017)
- SB072: Temporary suspension of safety functions (ESPE/AOPD muting)
- SB075: Controlling and monitoring safety gates with guard locking
- SB085: Driving and monitoring a hydraulic directional control valve
- SB086: Overrun control on linear-driven presses
- SB087: Driving/monitoring the position of a single hydraulic valve (poppet and directional control valve)
- SB088: Driving/monitoring the position of a dual hydraulic valve (poppet and directional control valve)
- SB089: Driving/monitoring the position of two hydraulic valves (poppet and directional control valve)
- SB092: Enable switch
- SB097: Monitoring muting lamps
- Changes to the operating manual
- Allocation of safety subroutine numbers - enable flags
- Contact addresses