6-46
Examples
Modular Block System: Hydraulic Presses
24 V
Reset
Lamps
E33.00
PSS SB DI8O8
Muting
Lamp 2
A32.07
E32.05
Muting
Lamp 1
A32.06
E32.04
E32.07
E32.06
E32.03
E32.02
E32.01
E32.00
Muting sensor
A32.02 E32.04 A32.03
E32.05
0 V
24 V
AOPD
Muting
Lamp 1
Muting
Lamp 2
E33.01
Reset
Muting
Monitoring muting lamps
Blocks used: SB072/MUTING and SB097/MUT_LAMP
In this example, the ESPE/AOPD, muting sensor and muting lamps are
connected to the SafetyBUS p module PSS SB DI808. The muting lamps
can either be driven via the negative-switching outputs (A32.06 and
A32.07) or via the positive-switching outputs (A32.02 and A32.03) in
conjunction with optocouplers.
Fig. 8-24: Monitoring muting lamps