Monitoring muting lamps, Examples – Pilz PSS SB HYD, Basic license User Manual

Page 282

Advertising
background image

6-46

Examples

Modular Block System: Hydraulic Presses

24 V

Reset

Lamps

E33.00

PSS SB DI8O8

Muting

Lamp 2

A32.07

E32.05

Muting

Lamp 1

A32.06

E32.04

E32.07

E32.06

E32.03

E32.02

E32.01

E32.00

Muting sensor

A32.02 E32.04 A32.03

E32.05

0 V

24 V

AOPD

Muting

Lamp 1

Muting

Lamp 2

E33.01

Reset

Muting

Monitoring muting lamps

Blocks used: SB072/MUTING and SB097/MUT_LAMP

In this example, the ESPE/AOPD, muting sensor and muting lamps are
connected to the SafetyBUS p module PSS SB DI808. The muting lamps
can either be driven via the negative-switching outputs (A32.06 and
A32.07) or via the positive-switching outputs (A32.02 and A32.03) in
conjunction with optocouplers.

Fig. 8-24: Monitoring muting lamps

Advertising