Pilz PSS SB HYD, Basic license User Manual

Page 257

Advertising
background image

8-21

Modular Block System: Hydraulic Presses

Fig. 8-14: Wiring diagram

Fig. 8-15: Timing diagram

24 V

Reset

E0.02

E0.03

pulsed output

A1.00

E0.00

PSS

Plant in operation

Close gate

PSS Start

E0.00

E0.02

E0.03

M80.00

1

1

1

1

1