Nexen LSCC-44 923632 User Manual

Page 6

Advertising
background image

FORM NO. L-21099-G-1209

6

aIr COnneCTIOnS

nOTe

For quick response, nexen recommends a quick exhaust

valve and short air lines between the Control Valves and

the product. align the air inlet ports to a down position

to allow condensation to drain out of the air chambers

of the product.

CAUTION

Low air pressure will cause slippage and
overheating. Excessive air pressure will
cause abrupt starts and stops, reducing
product life.

All Nexen pneumatically actuated devices require clean
and dry air, which meet or exceeds ISO 8573.1:2001
Class 4.4.3 quality.

The following are common air supply schemes used with
this product. These are examples and not an all-inclusive
list. All air circuits to be used with this product must be
designed following EN983 guidelines.

WARNING

Never exceed maximum operating
speeds listed for your product.
(See Table 2).

OPeraTIOn

TaBLe 2

CAUTION

The temperature limits for this
product line are 4.5-100 Degree
Celsius (40-220 Degree F).

CAUTION

Never exceed life of facing material. Facing

life depends on the volume of material and

the total energy over the life of the unit.

Expected life (in hrs) can be found by:

Time=Volume/(Power*Wear Rate).

Maximum rPM

PSI

Size 32

Size 44

Size 54

80

300

250

250

70

400

300

300

60

550

350

350

50

800

450

450

40

1000

750

750

WARNING

Ensure proper guarding of the product is

used. Nexen recommends the machine

builder design guarding in compliance

with OSHA 29 CFR 1910 “Occupational

Safety and Health Hazards”.

Advertising