Nexen DPC-11T 961200 User Manual

Page 13

Advertising
background image

10

FORM NO. L-20070-F-1209

BEARING PARTS REPLACEMENT (continued)

REFER TO FIGURE 9.
6. Remove Retaining Ring (Item 17).

7. Fully supporting the Housing (Item 5); press the Hub

(Item 1), out of the Housing and Bearings.

8. Remove Retaining Ring (Item 18).

9. Fully supporting the Housing (Item 5); push the

Bearing (Item 16), and Spacer (Item 17), out of the
Housing.

10. Clean bearing contact surfaces of both Housing

(Item 5), and Hub (Item 1) with fresh safety solvent.

11. Press new Bearings (Item 16), and Spacer (Item 7

into the Housing (Item 5).

NOTE

When installing new Bearings; carefully align

the Bearing O.D. with the Housing bore. Apply

Loctite

®

RC 601 or equivalent to the outer race

of the new Bearings.

12. Install Retaining Ring (Item 18).

13. Fully supporting the inner race of the new Bearings;

press the Hub (Item 1) into the Bearings, and
Housing.

14. Install Retaining Ring (Item 17).

15. Reverse Steps 1 through 5 to reassemble the DPC

Clutch. Be sure to note the chalk alignment marks
and tighten all screws to the recommended torque
(See Table 4).

CAUTION

Working with spring loaded or tension
loaded fasteners and devices can cause
injury. Wear safety glasses and take the
appropriate safety precautions.

Advertising