Troubleshooting – Nexen FMCBES-8-42 801481 User Manual

Page 7

Advertising
background image

7

FORM NO. L-20241-G-1209

TROUBLESHOOTING

SYMPTOM

PROBABLE CAUSE

SOLUTION

Failure to engage (clutch).

Air not getting to the FMCBES due to a control
valve malfunction.

Check for a control valve malfunction or
low air pressure and replace the control

valve if necessary.

Lack of lubrication on Stub Shaft spline.

Lubricate Stub Shaft spline.

Air leaks around the O-ring Seals.

Replace the O-ring Seals.

Failure to engage (brake).

Weak or broken Compression Springs.

Replace the Compression Springs.

Lack of lubrication on Stub Shaft spline.

Lubricate Stub Shaft spline.

Failure to disengage (clutch).

Unexhausted air due to a control valve malfunction. Check for a control valve malfunction and

replace the control valve if necessary.

Lack of lubrication on Stub Shaft spline.

Lubricate Stub Shaft spline.

Failure to disengage (brake).

Air not getting to the FMCBES due to a control
valve malfunction.

Check for a control valve malfunction or
low air pressure and replace the control

valve if necessary.

Lack of lubrication on Stub Shaft spline.

Lubricate Stub Shaft spline.

Loss of torque.

Air leaks around the O-ring Seals.

Replace the O-ring Seals.

Worn or dirty Friction Facings.

Replace the Friction Facings.

Ball

Bearing

Spring

Pin

Key

Stub

Shaft

Piston

Ball

Bearing

Ball

Bearings

Splined

Disc

Female

Pilot

Housing

Male

Pilot

O-Ring

Seals

Air

Chamber

Drive

Disc

Friction

Facings

Air to

Clutch

Compression

Spring

FIGURE 3

Set

Screw

Plug

Advertising