Nexen FMBS-1375 801981 User Manual

Page 6

Advertising
background image

6

FORM NO. L-21272-A-1212

LUBRICATOR DRIP RATE SETTINGS

1. Close and disconnect the air line from the unit.

2. Turn the Lubricator Adjustment Knob counterclockwise

three complete turns.

3. Open the air line.

4. Close the air line to the unit when a drop of oil forms

in the Lubricator Sight Gage.

Each FMBS is provided with a Housing Guard. Install
the Housing Guard so one of the ribs of the FMBS input
housing is directly beneath the clamp on the Housing Guard.
Tighten screws to 35 in-lbs [4 Nm].

Waterproof guards are also available. Purchase waterproof
guards from your local Nexen Distributor.

HOUSING GUARD INSTALLATION

FIGURE 3

HOUSING GUARD

WARNING

Always have the Housing Guard in

place when operating the FMBS (See

Figure 3).

NOTE

Nexen pneumatically actuated devices require clean, pressure regulated air for maximum performance

and life. All seals in Nexen Pneumatically operated devices are lubricated for life and do not require

additional lubrication.
However, some customers prefer to use an air line lubricator, which injects oil into the pressurized air,

forcing an oil mist into the air chamber. This is acceptable, but care must be taken to ensure once an air

mist lubrication system is used, it is continually used over the life of the product as the oil mist may wash

free the factory installed lubrication.
Locate the lubricator above and within ten feet of the product, and use low viscosity oil such as SAE-10.
Synthetic lubricants are not recommended.
Nexen product's bearings are shielded and pre-lubricated, and require no further lubrication.

5. Connect the air line to the unit.

6. Turn the Lubricator Adjustment Knob clockwise until

closed.

7. Turn the Lubricator Adjustment Knob counterclockwise

one-third turn.

8. Open the air line to the unit.

LUBRICATION

CAUTION

These settings are for Nexen supplied

lubricators. If you are not using a Nexen

lubricator, calibration must follow the

manufacturer's suggested procedure.