7

FORM NO. L-21272-A-1212

Nexen's FMBS engages when the air supply is exhausted
by the control valve or when there is a loss of air supply,
and disengage when air pressure is applied (See Table 1).

TABLE 1

AIR CONNECTIONS

NOTE

For quick response, Nexen recommends a quick exhaust

valve and short air lines between the Control Valves and

the product. Align the air inlet ports to a down position

to allow condensation to drain out of the air chambers of

the product.

CAUTION

Low air pressure will cause slippage and

overheating. Excessive air pressure will

cause abrupt starts and stops, reducing

product life.

All Nexen pneumatically actuated devices require clean
and dry air, which meet or exceeds ISO 8573.1:2001
Class 4.4.3 quality.

For maximum performance, mount the control valve as
close to the FMBS as possible.

The following is a common air supply scheme used with
this product. This is an example and not an all-inclusive
list. All air circuits to be used with this product must be
designed following EN983 guidelines.

WARNING

Never exceed maximum operating
speeds listed for your product.

(See Table 2).

OPERATION

TABLE 2

Model

Max RPM

FMBS 1125-1625

1,800

CAUTION

The temperature limits for this
product line are 4.5-104 Degree
Celsius (40-220 Degree F).

WARNING

Ensure proper guarding of the product is used.

Nexen recommends the machine builder

design guarding in compliance with OSHA 29

CFR 1910 “Occupational Safety and Health

Hazards”.

CAUTION

Never exceed life of facing material. Facing

life depends on the volume of material and the

total energy over the life of the unit. Expected

life (in hrs) can be found by: Time=Volume/

(Power*Wear Rate).

MINIMUM DISENGAGEMENT AIR PRESSURES

MODEL

AIR PRESSURE

FMBS-1125

N/A

FMBS-1375

55 PSI

FMBS-1625

90 PSI

CAUTION

Do not use more air pressure than
required to release the brake (120
psi maximum).

CAUTION

Large amounts of friction material dust are

generated with frequent dynamic cycling.

Ensure all appropriate air quality and PPE

requirements are being addressed.