Rstc1100 profibus table of parameters – Nexen RSTC1100 964528 User Manual

Page 7

Advertising
background image

FORM NO. L-21230-B-0908

4

RSTC1100 PROFIBUS TABLE OF PARAMETERS

Parameter Name

Type

Page

Parameter Name

Type

Page

Profi bus Comm Setup

Setup

0

Profi bus Device Address

Read/Write

5

33

Standby Output

Read/Write

7

Diagnostics

34

Web Material Selection

Read/Write

7

2

Alarm Status

Read Only

5

35

Average Web Width

Read/Write

7

3

Load Cell 1 Tension

Read Only

5

36

Maximum Roll Diameter

Read/Write

7

4

Load Cell 2 Tension

Read Only

5

37

Minimum Roll Diameter

Read/Write

7

5

Control Output

Read Only

5

Control

6

Roll Diameter

Read Only

5

8

Run/Stop

Write Only

7

7

Run/Stop Status

Read Only

5

10

Splice A

Write Only

7

9

Splice A Status

Read Only

5

11

Splice B

Write Only

7

11

Splice B Status

Read Only

6

41

Panel Write Enable

Read Only

7

13

Adaptation

Read Only

6

42

Manual/Automatic Mode

Read/Write

7

14

Taper Tension Setpoint

Read Only

6

43

Manual Output Level

Read/Write

7

Tuning

44

Alarm Acknowledge

Write Only

8

15

Taper Tension Enable

Read/Write

6

45

Output On/Off

Read/Write

8

16

Tension Setpoint

Read/Write

6

Signal Selection

17

Taper Factor

Read/Write

6

46

Run/Stop Signal Selection

Read/Write

8

18

Taper Delay

Read/Write

6

Diameter Sensor Calibration

19

Gain

Read/Write

6

47

Diameter Sensor Installed

Read/Write

8

20

Stabilization

Read/Write

6

48

Diameter-Core Size

Read/Write

8

21

Initial Adaptation

Read/Write

6

49

Diameter-Large Roll Size

Read/Write

8

22

Splice Adaptation

Read/Write

6

50

Diameter Measure Flag

Read/Write

8

23

Adaptation Rate

Read/Write

6

Tension Calibration

24

Remote Tension Setpoint Enable Read/Write

6

38

Minimum Tension Setpoint

Read/Write

8

Setup

39

Maximum Tension Setpoint

Read/Write

8

25

Tension Monitor Enable

Read/Write

6

40

Tension Calibration Set

Read/Write

8

26

Tension Alarm Tolerance

Read/Write

6

51

Load Cell Measure Flag

Read/Write

9

27

Alarm Output Type

Read/Write

6

52

Tare Tension-Calibration Set 1

Read/Write

9

28

Torque Actuator

Read/Write

7

53

Span Tension-Calibration Set 1

Read/Write

9

29

Torque Actuator Inertia

Read/Write

7

54

Tare Tension-Calibration Set 2

Read/Write

9

30

Tension Zone Selection

Read/Write

7

55

Span Tension-Calibration Set 2

Read/Write

9

31

Minimum Output

Read/Write

7

56

Tare Tension-Calibration Set 3

Read/Write

10

32

Maximum Output

Read/Write

7

57

Span Tension-Calibration Set 3

Read/Write

10