Nexen TCC Caliper 835121 User Manual

Page 6

Advertising
background image

3

FORM NO. L-20065-K-0110

FIGURE 5

Housing

(Item 8)

Elbow Fitting

(Item 15)

or

Tee Fitting

(Item 16)

Caliper

Assembly Half

Cap Screws

(Item 18)

SHAFT MOUNTED TCB

REFER TO FIGURE 5.
1. Using Cap Screws (Item 36) and Lock Washers

(Item 37), fasten Torque Arm (Item 32) onto Housing
(Item 8).

NOTE

Use Cap Screws (Item 34) on TCB-20.

2. Using Cap Screws (Item 18) and Lock Washers

(Item 19), secure one-half of a Caliper Assembly
to flange side of Housing (Item 8). Tighten Cap
Screws to 7 ft-lbs [9.5 Nm] torque.

NOTE

Internal springs return the Caliper Piston to the

disengaged position to guarantee clearance

between Friction Facing and Rotor when no air

pressure is being applied. The use of this spring

is optional; the low air pressure setting is more

sensitive without the springs. Refer to PARTS

REPLACEMENT for spring removal.

3. Install an Elbow Fitting (Item 15) or a Tee Fitting

(Item 16) as required into each caliper half.

4. Slide Housing assembly onto shaft and tighten Set

Screw (Item 26) to torque recommended in Table 1.

NOTE

Provide a minimum clearance of 3" [76.2 mm]

between both sides of Housing and other

machine components.

5. Install rotor Hub (Item 1).

NOTE

See the following section for Rotor Hub

installation instructions.

Lock Washers

(Item 19)

INSTALLATION continued

TABLE 1 Tightening Torques

Description

TCB-10

TCB-14

TCB-20

Lock Nut

(Item 38)

32 ft-lbs

[43.0 Nm]

32 ft-lbs

[43.0 Nm]

32 ft-lbs

[43.0 Nm]

Set Screw

(Item 7)

23 ft-lbs

[30.9 Nm]

50 ft-lbs

[67.2 Nm]

166 ft-lbs

[223.1 Nm]

Jam Nut

(Item 10)

200 ft-lbs

[268.8 Nm]

200 ft-lbs

[268.8 Nm]

200 ft-lbs

[268.8 Nm]

Cap Screw

(Item 18)

27 ft-lbs

[36.4 Nm]

27 ft-lbs

[36.4 Nm]

27 ft-lbs

[36.4 Nm]

Set Screw

(Item 26)

23 ft-lbs

[30.9 Nm]

50 ft-lbs

[67.2 Nm]

166 ft-lbs

[223.1 Nm