4

FORM NO. L-20065-K-0110

ROTOR HUB

INSTALLATION continued

NOTE

The following sections are arranged by rotor

type. Verity that you are in the correct section

for your model.

1. Insert Key (Item 6) into shaft keyway and align Hub

(Item 1) keyway with shaft keyway and slide Hub
Assembly (Items 1-5) onto shaft.

NOTE

Allow 1/16" [16 mm] gap between Friction

Facings and Rotor Disc.

2. Tighten Set Screw (Item 7) to recommended torque

(See Table 2).

TABLE 2 Tightening Torques

TABLE 3 Q.D. Bushing Specifications

Description

TCB-10

TCB-14

TCB-20

Lock Nut

(Item 38)

32 ft-lbs

[43.0 Nm]

32 ft-lbs

[43.0 Nm]

32 ft-lbs

[43.0 Nm]

Set Screw

(Item 7)

23 ft-lbs

[30.9 Nm]

50 ft-lbs

[67.2 Nm]

166 ft-lbs

[223.1 Nm]

Jam Nut

(Item 10)

200 ft-lbs

[268.8 Nm]

200 ft-lbs

[268.8 Nm]

200 ft-lbs

[268.8 Nm]

Cap Screw

(Item 18)

27 ft-lbs

[36.4 Nm]

27 ft-lbs

[36.4 Nm]

27 ft-lbs

[36.4 Nm]

Set Screw

(Item 26)

23 ft-lbs

[30.9 Nm]

50 ft-lbs

[67.2 Nm]

166 ft-lbs

[223.1 Nm

Model

Bushing

Tightening Torque

TCB-10

JA

5 ft-lbs [6.4 Nm]

TCB-14

SK

15 ft-lbs [20.2 Nm]

TCB-20

J

135 ft-lbs [182.2 Nm]

Q.D. (TAPERED BORE) ROTOR HUB

CAUTION

Thoroughly inspect the tapered bore of hub
and tapered surfaces of the Q.D. bushing.
Remove any dirt, grease, or foreign material.
Do not use lubricants for this installation.

1. Assemble Q.D. bushing into hub, aligning untapped

holes of Q.D. bushing with tapered holes in hub.

2. Loosely insert pull-up bolts with Lock Washers into

Q.D. bushing and hub.

NOTE

Do not use lubricants or thread locking

compounds on these bolts.

3. With Key in shaft keyseat, slide the Hub Assembly

(Items 1-5) onto shaft.

4. Tighten pull-up bolts alternately and evenly to

recommended torque in Table 3.

NOTE

Runout is minimized if a Dial Indicator is used

as the Q.D. bushing pull-up bolts are tightened.

Place the contact tip of Dial Indicator on the

machined surface of the Rotor to measure

runout. Runout must be less than 0.015'' [0.381

mm] TIR. (See Figure 6).

NOTE

Proceed with FRICTION FACING & CALIPER

installation.

CAUTION

The tightening force on the pull-up bolts
is multiplied several times by the wedging
action of the tapered surface. If extreme
tightening force is applied or if a lubricant
is used, bursting pressure will be created
in the splined hub. Follow recommended
tightening torque listed in Table 3.