Installation instructions, Electrical connection - (continued), Connecting to a four wire electrical system – Dacor EOR User Manual

Page 12

Advertising
background image

10

Installation Instructions

Connecting to a Four Wire Electrical

System

Separate the wires coming out of the appliance conduit.

1.

Connect the white wire from the appliance conduit to the

2.

white (neutral) supply wire in the junction box.

Connect the black wire from the appliance conduit to the

3.

black (L1) supply wire in the junction box.

Connect the red wire from the appliance conduit to the

4.

red (L2) supply wire in the junction box.

Connect the green wire from the appliance conduit to the

5.

green (ground) wire in the junction box.

Connecting to a Three Wire Electrical

System - Where Local Codes Permit

WARNING

Do not connect the green appliance conduit wire to the

neutral (white) junction box wire unless local building

codes permit.

Separate the wires coming out of the

1.

appliance conduit.

Connect the

2.

green and white wires from the appliance

conduit to the white (neutral) supply wire in the junction

box.

Connect the black wire from the appliance conduit to the

3.

black (L1) supply wire in the junction box.

Connect the red wire from the

4.

appliance conduit to the

red (L2) supply wire in the junction box.

Incoming power

Wire nut,

3 places

Junction box

Conduit to

oven

three Wire Connection

Incoming power

Wire nut,

4 places

Junction box

Conduit to

oven

Four Wire Connection

Electrical Connection - (continued)