Installation Specifications

Installation Planning

WARNING

Observe all governing codes and ordinances during plan-

ning and installation. Contact your local building depart-

ment for further information.

IMPORtANt

Locate the junction box so that the oven may be easily

disconnected in the event that it needs to be removed

from the wall completely for service.

If the oven is not installed level it may deliver poor or

inconsistent baking results.

A qualified technician must complete the installation of

this built-in appliance. Proper installation is the respon-

sibility of the customer.

Carefully check the location where the oven is to be

installed. The oven should be placed for convenient

access. Make certain that electrical power, meeting

the specifications on page 4, can be provided in the

selected location.

Minimum Interior Cabinet Depth: 24” (61.0 cm)

Dacor recommends installing the electrical junction box

in the one of the locations shown.

Install the junction box in a location that allows the oven

to be removed from the the cut out for service without

being disconnected.

Plan the installation so that all minimum clearances are

met or exceeded. Dimensions shown provide mini-

mum clearances, unless otherwise noted. Be certain

that proper clearance is provided for the oven door

when it is in the open position according the Product

Dimensions.

Cabinet cutout dimensions must be used as indicated.

The specified minimum cabinet depth and width must

be provided. The cabinet depth and width must com-

pletely enclose the recessed portion of the oven.

All contact surfaces between the appliance and the cabi-

net must be solid and level.

Provide a platform within the cabinet to support the

oven. It must be installed level and straight. The top

edge of the platform must be flush with the cut out at

the front of the cabinet. There are no provisions to level

the oven after it has been installed. 3/4” (1.9 cm) thick

plywood is recommended.

Model

Number

Minimum Cabinet

Width (N)

Minimum Cut Out

Width (P)

Minimum Cut out

Height (R)

EORS127/

MORS127

27” (68.6 cm)

25 ½” (64.8 cm)

27 5/8” (70.2 cm)

EORS130/

MOCS130

30” (76.2 cm)

28 ½” (72.4 cm))

EORS136

36” (91.4 cm)

34 ½” (87.6 cm)

27 ¾” (70.5 cm)

EORX227/

MORX227

27” (68.6 cm)

25 ½” (64.8 cm)

49 1/8” (124.8 cm)

EORX230/

MORX230

30” (76.2 cm)

28 ½” (72.4 cm)

Cabinet Dimensions

X = Number of convection ovens, see page 3

Advertising
This manual is related to the following products:

MOR