11

Installation Instructions

Clamps

Bare metal

Insulating device

4 AWG wire

(minimum)

three Wire Connection with External Ground

Conduit to

oven

Incoming

Power

Wire Nut,

4 Places

Junction Box

Separate 10 AWG

Wire Minimum

Clamp wire tightly

to pipe

Connecting to a Three Wire Electrical

System with External Ground - Where Local

Codes Permit

WARNING

Do not ground the appliance to a gas supply pipe or

hot water pipe.

If connecting the ground wire to a grounded cold water

pipe, connect using a separate copper grounding

wire (No. 10 minimum) and a clamp with an external

grounding screw. The grounded cold water pipe must

have metal continuity to electrical ground and must not

be interrupted by insulating materials. Any insulating

materials must be jumped, with a minimum, 4 AWG

wire to establish continuity to ground.

NOtE

If the junction box has been properly grounded by a

licensed electrician, the green (ground) wire from the

appliance conduit may be connected to the junction box

using a loop terminal.

to connect the green appliance conduit wire to a

grounded cold water pipe:

Separate the wires coming out of the

1.

appliance conduit.

Connect the white wire

2.

from the appliance conduit to the

white (neutral) supply wire in the junction box.

Connect the black wire from the appliance conduit to the

3.

black (L1) supply wire in the junction box.

Connect the red wire from the

4.

appliance conduit to the

red (L2) supply wire in the junction box.

Connect the green wire from the

5.

appliance conduit to a

grounded cold water pipe as shown. Jumper any insu-

lating materials as shown above with a length of No. 4

copper wire. Securely clamp the wire to bare metal at

both ends.

Insulated Pipe Jumper