background image

www.desatech.com

116986-01B

1

CONNECTING TO GAS SUPPLY

WARNING: This appliance

requires a 1/2" NPT (National

Pipe Thread) inlet connection

to the shutoff valve.

WARNING: A qualified service

person must connect heater to gas

supply. Follow all local codes.

CAUTION: Never connect

propane/LP fireplace directly

to the propane/LP supply. This

heater requires an external regu-

lator (not supplied). Install the

external regulator between the

heater and propane/LP supply.

WARNING: Never connect

natural gas fireplace to private

(non-utility) gas wells. This gas

is commonly known as wellhead

gas.

INsTallaTIoN

Continued

Fitting

Flexible Gas Hose
(if allowed by local codes)

Figure 10 - Attaching Flexible Gas Hose

to Regulator

Installation Items Needed

Before installing heater, make sure you have the

items listed below.

• external regulator (for propane/LP units only,

supplied by installer)

• piping (check local codes)

• sealant (resistant to propane/LP gas)

• equipment shutoff valve *

• test gauge connection *

• sediment trap

• tee joint

• pipe wrench

• approved flexible gas line with gas connector

(if allowed by local codes)

* A CSA design-certified equipment shutoff valve

with 1/8" NPT tap is an acceptable alternative to

test gauge connection. Purchase the optional CSA

design-certified equipment shutoff valve from your

dealer. See Accessories, page 25.

For propane/LP units, the installer must supply

an external regulator. The external regulator will

reduce incoming gas pressure. You must reduce

incoming gas pressure to between 11 and 14 inches

of water. If you do not reduce incoming gas pres-

sure, heater regulator damage could occur. Install

external regulator with the vent pointing down

as shown in Figure 11. Pointing the vent down

protects it from freezing rain or sleet.

CAUTION: Use only new, black

iron or steel pipe. Internally-tinned

copper tubing may be used in

certain areas. Check your local

codes. Use pipe of 1/2" diameter or

greater to allow proper gas volume

to heater. If pipe is too small, undue

loss of volume will occur.

Figure 11 - External Regulator With Vent

Pointing Down

Propane/LP
Supply Tank

External
Regulator

Vent
Pointing
Down

Installation Items Needed

• control cover kit (provided with heater)

• approved flexible gas hose (if allowed by local

codes)

• sealant (resistant to propane/LP gas, not

provided)

1. Apply pipe joint sealant lightly to male threads

of gas fitting (not provided). Connect approved

flexible gas hose to inlet side of gas control (see

Figure 10). IMPORTANT: Hold gas fitting with

wrench when connecting flexible gas hose.

2. Position heater assembly in fireplace.

3. Connect to gas supply. See Connecting to

Gas Supply.