Operating heater – Desa VF-24N-MHD User Manual

Page 16

Advertising
background image

www.desatech.com

116986-01B

16

6. Press the buttons

and at the same

time. A short acoustic signal confirms the

start sequence has begun.

Further short acoustic signals (0.2 sec., 1 Hz)

indicate the ignition process until it is com-

pleted and main gas flows. If pilot is already

lit, motor will turn on (max. flame height)

while buttons are pressed down. If pilot does

not light, see Troubleshooting, page 21.

7. Press to turn on main burner and in-

crease flame height. Press to decrease

flame height and shut off main burner.

8. Short tapping of either button allows incre-

mental change in flame height.

9. Press OFF button to switch off main gas

and pilot gas.

FUNCTIONS OF

REMOTE CONTROL

Battery

• After the charged battery has been correctly

installed, the remote hand set is ready for

operations.

• Remove the battery if the remote handset

will not be used more than one year.

Changing The Code

The control is radio frequency operated. A code

(chosen from among 4,000 available codes) is

preset for all valves, but can be changed if re-

quired (15 additional codes available). Change

DIP switch position. (The DIP switch is located

inside the hand held control at the top of the

battery compartment.) Then press the receiver's

reset button on the bottom of the receiver module

until you hear a second (longer) signal. When

pressing the button on the remote handset

in the following 20 sec., the receiver learns the

new code.

Shut-off Procedure

To save battery power; press to turn main

gas to pilot gas. Press OFF button to shut off

the device including pilot flame. The device can

be shut off with ON/OFF switch, thus disabling

the remote hand set.
Setting The Display ( °C/24h and °F /12h)

Press and hold OFF and

until display

changes from °F (and 12 hour clock) to °C (and

24 hour clock) or vice versa.
Setting The Time

• After connecting the battery or by simulta-

neously pressing and the display will

start to flash. You are in the set mode.

• From SET mode press to set the hour and

to set the minute.

• Wait or press OFF to return to the manual

mode.

Battery Replacement

Remote handset battery needs to be changed

when LED is dim. Battery life expectancy is 2

to 3 years. Replacement is recommended at the

beginning of heating season. Battery needs to be

changed when acoustic error message appears

during ignition (see Identifying Error Signals

from Receiver on page 24).
Changing Mode of Operation

• Press the SET button quickly to change the

mode of operation in the following order:

MAN, TEMP, TEMP, TIMER.

• Manual flame height adjustment (MAN ap-

pears on display): Press to turn on the fire

(main burner) or to increase flame height.

Press to decrease flame or to go down

to pilot only. The receiver acknowledges the

transmission with an acoustic signal.

• The day time temperature mode ( TEMP ap-

pears on display): The sensor in the transmitter

measures room temperature. The controller

compares the room temperature with set tem-

perature and sends a signal to the receiver to

turn the gas valve motor up or down, to adjust

the flame height accordingly.

• The nighttime setback temperature (

TEMP

appears on display): The sensor in the

transmitter measures the temperature and

adjusts it according to the nighttime setback

temperature. There is a bigger temperature

differential during this cycle.

oPeRaTING HeaTeR

Continued

SET

OFF

STAND

BY

Figure 17 - Control Panel for Hand-Held Remote

Advertising