4. Check all joints from equipment shutoff valve

to control valve (see Figure 14 or 15). Apply

noncorrosive leak detection fluid to all joints.

Bubbles forming show a leak.

5. Correct all leaks at once.

6. Light heater (see Operating Heater, page 15).

Check all other internal joints for leaks.

7. Turn off heater (see To Turn Off Gas to Appli-

ance, page 18).

Figure 13 - Equipment Shutoff Valve

Open

Closed

Equipment
Shutoff Valve

Figure 15 - Checking Gas Joints for

Propane/LP Gas

Control Valve Location

Propane/LP
Supply Tank

Equipment Shutoff Valve

Figure 14 - Checking Gas Joints for

Natural Gas

Gas Meter

Equipment Shutoff Valve

Control Valve
Location

4. Check all joints of gas supply piping system.

Apply noncorrosive leak detection fluid to all

joints. Bubbles forming show a leak.

5. Correct all leaks at once.

6. Reconnect heater and equipment shutoff

valve to gas supply. Check reconnected fit-

tings for leaks.

Test Pressures Equal To or Less Than
1/2 PSIG (3.5 kPa)

1. Close equipment shutoff valve (see Figure 13).

2. Pressurize supply piping system by either

opening propane/LP supply tank valve for

propane/LP gas or opening main gas valve

located on or near gas meter for natural gas

or using compressed air.

3. Check all joints from gas meter to equipment

shutoff valve for natural gas or propane/LP sup-

ply to equipment shutoff valve for propane/LP

(see Figure 14 or 15). Apply noncorrosive leak

detection fluid to all joints. Bubbles forming

show a leak.

4. Correct all leaks at once.
PRESSURE TESTING HEATER GAS
CONNECTIONS

1. Open equipment shutoff valve (see Figure 13).

2. Open main gas valve located on or near gas

meter for natural gas or open propane/LP

supply tank valve.

3. Make sure control knob of heater is in the OFF

position.

Place Lava Rock and
Small Decorative
Logs in Front of
Burner

Place
Glowing
Embers
on Burner
Ports

Figure 16 - Placement of Embers and

Lava Rock

ADDING EMBERS, LAVA ROCK AND
DECORATIVE LOGS

The effect of glowing embers is created by placing

ember material on the front burner.

1. Make sure the heater is OFF and has cooled

if it has been running.

2. Gently remove embers from the bag using

gloves or tweezers (recommended to prevent

skin irritation). Separate the pieces.

3. Place ember pieces, one at a time, over ports

on flat burner (see Figure 16). Do NOT place

ember material anywhere else on the unit.

Use only ember material supplied with unit (12

one inch square pieces). Excessive ember mate-

rial may produce carbon monoxide or soot.

Advertising