Inspecting burners, Operating heater – Desa VF-24N-MHD User Manual

Page 18

Advertising
background image

www.desatech.com

116986-01B

18

Lighting with Piezo Ignitor

1. Disconnect ignitor cable from receiver and

connect to Piezo Ignitor Tab (see Figure 18,

page 17 and Wiring Diagram on page 24).

2. STOP! Read safety information on page 15,

3. Make sure equipment shutoff valve is fully

open.

4. Turn Motor-knob clockwise

to the

OFF position.

5. Wait (5) minutes to clear any gas and

then smell for gas around heater and near

floor. If you smell gas, STOP! follow "B"

on page 14.

6. ON/OFF switch in "—" ON position.

7. MAN-knob on valve is in MAN position (see

Figure 18, page 17), When in MAN position

you can see a metallic core.

8. Push and hold down metal core fully with

a pen while the pilot gas flows.

9. Press and release piezo ignitor button until

pilot lights.

10. Continue holding down metal core for

about 10 seconds and then release the metal

core. Pilot should stay lit. If not, repeat steps

one through 4, page 17.

11. Turn MAN-Knob to ON position - main gas

flows.

12. Turn Motor-knob to adjust flame. Knob has

a slipping clutch that allows manual flame

height adjustment.

TO TURN GAS OFF

TO APPLIANCE

Shutting Off Heater

Press OFF button on remote control to switch

off main gas and pilot gas or manually turn

Motor-Knob clockwise

to the "O" OFF

position.
Shutting Off Burner Only (pilot stays lit)

Press to decrease the flame height and shut off

main burner.

INsPeCTING BURNeRs

Check pilot flame pattern and burner flame pat-

terns often.

PILOT FLAME PATTERN

Figure 20 shows a correct pilot flame pattern.

Figure 21 shows an incorrect pilot flame pattern.

The incorrect pilot flame is not touching the

thermocouple. When the thermocouple cools, the

heater will shut down.

If pilot flame pattern is incorrect, as shown in

Figure 21

• turn heater off (see To Turn Off Gas to Appli-

ance, above or page 17)

• see Troubleshooting, page 20
Note:

The pilot flame on natural gas units will

have a slight curve, but flame should be blue and

have no yellow or orange color.

oPeRaTING HeaTeR

Continued

Thermocouple

Thermocouple

Figure 21 - Incorrect Pilot Flame Pattern

(Natural Gas Pilot Shown)

Figure 20 - Correct Pilot Flame Pattern

(Natural Gas Pilot Shown)

Advertising