Table 3–11
describes the parameters in the Power Supply Current
parameters of the PowerPlay Early Power Estimator spreadsheet.
Table 3–11. Power Supply Current Information
Column Heading
Description
I
CC
INT
This shows the total current drawn from the I
CCINT
supply (in A).
I
CC
IO
This shows the total current drawn from the I
CCIO
power rail(s). See the I/O sheet for
details on the current drawn from each I/O rail.
I
C C I O
includes any current drawn through the I/O into off-chip termination resistors.
This can result in I
C C I O
values that are higher than the reported I/O thermal power,
since this off-chip current is dissipated as heat elsewhere and does not factor into the
calculation of device temperature.