INSTALLATION

Continued

Note:

If you are using a mantel with your

heater, use the following instructions. If
your heater is built-in, see For Built-In In-
stallation
on page 11.

1.

Screen and hood should be removed
from fireplace (see page 9). Remove
log set and set aside.

2.

Install snap bushings found in hardware
kit into both holes in rear of blower
control shield (see Figure 14).

3.

Make sure the wire harness is firmly
connected to the terminals on the blower
bracket assembly.

4.

Note the wire locations on back of
AUTO/OFF/ON switch. Carefully re-
move red wire from the AUTO termi-
nal and blue wire from the ON termi-
nal. Black wire can remain on the
middle or OFF terminal (see Figure 15).

5.

Carefully disconnect green and white
wires from power cord harness at their
insulated connectors.

6.

In top of the heater cabinet, locate the
four mounting holes on the outer cas-
ing. Align these four holes with those
on the blower bracket assembly. Attach
blower bracket assembly to the outer
casing with 4 - #10 screws provided
(see Figure 15).

7.

Route the wire harness through the hole
to the left side of heat deflector. Pull
wire harness through lower opening to
the left of the blower control shield. (see
Figure 15).

8.

Insert the 4 wire harness into one of the
round holes in the rear of the blower con-
trol shield and through the rectangular
hole in the front of shield (see Figure 15).

Snap
Bushing

Figure 14 - Installing Snap Bushings

Blower
Control
Shield

Figure 15 - Installing Blower Bracket Assembly

Switch Plate

4.

Place brass trim on the shoulder screws
located on the side and top of the fireplace.
Firmly snap the brass trim over the shoul-
der screws on fireplace (see Figure 13).

5.

Place mantel base close to wall in de-
sired fireplace location.

6.

Install gas line. See Connecting To Gas
Supply
, page 12

7.

Carefully place fireplace on mantel base
and center left to right. Check for gas leaks.
See Checking Gas Connections, page 14.

8.

Refer to instructions provided with the
mantel for permanent attachment to wall.

9.

Slide mantel around fireplace. Be care-
ful not to damage wall or mantel.

10. Adjust assembly to remove any gaps.

From back side of fireplace, attach two
2" wood screws through base mount-
ing blocks attached to bottom sides of
mantel into base (see instructions pro-
vided with mantel).

11. Attach remaining two 3" wood screws

from hardware pack through openings
inside of fireplace sides into the mantel.
See Figure 12, page 9, for screw hole
location.

Figure 13 - Attaching Brass Trim to Fireplace

AUT

O

OF

F

ON

Shoulder
Screws

Assembled
Brass Trim

AUT

O

OF

F

ON

Wire Harness

Blower Bracket
Assembly

Screw

Power
Cord

Blower
Control
Shield

Shield Cover

Wire
Harness

Switch

Heat
Deflector

Wiring
Routing Hole

Blue

Red

CAUTION: Label all wires prior

to disconnection when servicing
controls. Wiring errors can cause
improper and dangerous operation.

CAUTION: Verify proper op-

eration after servicing.

INSTALLING BLOWER
ASSEMBLY - GA3450T

Advertising