105442

VENT-FREE PROPANE/LP BAY FRONT FIREPLACE

CF26PR

For more information, visit www.desatech.com

O

POSIT

PO

Open

Closed

Equipment
Shutoff
Valve

Figure 24 - Checking Gas Joints (Shown with Optional Mantel)

Figure 23 - Equipment Shutoff Valve

Equipment
Shutoff
Valve

Propane/LP

Supply Tank

Pressure Testing Gas Supply
Piping System

Test Pressures In Excess Of 1/2 PSIG
(3.5 kPa)

1.

Disconnect appliance with its appli-
ance main gas valve (control valve)
and equipment shutoff valve from gas
supply piping system. Pressures in ex-
cess of 1/2 psig will damage fireplace
regulator.

2.

Cap off open end of gas pipe where
equipment shutoff valve was con-
nected.

3.

Pressurize supply piping system by ei-
ther using compressed air or opening
propane/LP supply tank valve.

4.

Check all joints of gas supply piping
system. Apply mixture of liquid soap
and water to gas joints. Bubbles form-
ing show a leak.

5.

Correct all leaks at once.

6.

Reconnect heater and equipment
shutoff valve to gas supply. Check re-
connected fittings for leaks.

INSTALLATION

Continued

CHECKING GAS
CONNECTIONS

WARNING: Test all gas pip-

ing and connections for leaks
after installing or servicing. Cor-
rect all leaks at once.

WARNING: Never use an open

flame to check for a leak. Apply a
mixture of liquid soap and water
to all joints. Bubbles forming show
a leak. Correct all leaks at once.

CAUTION: Make sure external

regulator has been installed be-
tween propane/LP supply and fire-
place. See guidelines under

Con-

necting to Gas Supply, page 12.

Test Pressures Equal To or Less Than
1/2 PSIG (3.5 kPa)

1.

Close equipment shutoff valve (see
Figure 23).

2.

Pressurize supply piping system by ei-
ther using compressed air or opening
propane/LP supply tank valve.

3.

Check all joints from propane/LP sup-
ply tank to equipment shutoff valve (see
Figure 24). Apply mixture of liquid
soap and water to gas joints. Bubbles
forming show a leak.

4.

Correct all leaks at once.

Pressure Testing Fireplace Gas
Connections

1.

Open equipment shutoff valve (see
Figure 23).

2.

Open propane/LP supply tank valve.

3.

Make sure control knob of fireplace is
in the OFF position.

4.

Check all joints from equipment shutoff
valve to thermostat gas valve (see Fig-
ure 22, page 13). Apply mixture of liq-
uid soap and water to gas joints.
Bubbles forming show a leak.

5.

Correct all leaks at once.

6.

Light fireplace (see Operating Fire-
place
, pages 16 through 18). Check all
other internal joints for leaks.

7.

Turn off fireplace (see To Turn Off Gas
to Appliance
, page 17).

8.

Replace front panel.