Introduction, Selecting location – Desa GL36STEP User Manual

Page 5

Advertising
background image

www.desatech.com

55173-F

5

Figure 2 - Typical Two-Sided Fireplace

Installation

INTRODUCTION

Models GL36ST/P and GL36STE/EP are decora-

tive gas appliances that use a millivolt gas control

and piezo pilot or an electronic gas control valve

with an electronic ignition system respectively.

These systems require a 6", B-type venting system

for operation.
The 6" B-type vent is not supplied by DESA.

For installation guidelines, check your B-vent

instructions.

WARNING: This gas appli-

ance must not be connected to

a chimney flue servicing a solid

fuel burning appliance.

Models GL36ST and GL36STE are smooth face

units for natural gas only. The GL36STP and

GL36STEP are smooth face units for propane/LP

gas only. To determine which type of gas your unit

is approved and tested for, check the rating plate on

the lift-out plate located inside the firebox under

the access panel.

BEFORE YOU BEGIN

Before beginning the installation of your appli-

ance, read these instructions through completely.
This DESA appliance and its approved compo-

nents are safe when installed according to this

installation manual and are operated as recom-

mended by DESA. Unless you use DESA approved

components tested for this appliance, YOU MAY

CAUSE A FIRE HAZARD!
The DESA warranty will be voided by and DESA dis-

claims any responsibility for the following actions :
A) Modification of the appliance or any of the

components manufactured by DESA unless

otherwise permitted by DESA.

B) Use of any component part not approved by

DESA in combination with this appliance.

C) Installation and/or operation in a manner other

than instructed in this manual.

D) The burning of anything other than the type of

gas approved for use in this gas appliance.

This appliance, when installed, must be electrically

grounded in accordance with local codes or, in the

absence of local codes, with the National Electri-

cal Code, ANSI/NFPA 70-1987 and the CSA C22.1

Canadian Electrical Code for Canada.
The installation must conform with local codes

or, in the absence of local codes, with the current

National Fuel Gas Code, ANSI Z223.1/NFPA 54

or with the current CAN/CGA B149 Installation

Codes for Canada.

This appliance complies with ANSI Z21.50B-1990

and CAM/CGA-2.22-M89 as a Vented Gas Ap-

pliance and is listed and tested by the Omni Test

Laboratories.

WARNING: Installation of

this appliance should be done

by a qualified service person

well trained in the installation

of such appliances. You will

also need a building permit from

your local Building and Safety

Commissioner before installing

this appliance; otherwise your

insurance company may not

cover this appliance.

NOTICE: This appliance is not

intended to be used as a primary

source of heat.

SELECTING LOCATION

To determine the safest and most efficient location

for your appliance, you must take into consider-

ation the following guidelines:
1. The location must allow for proper clearances

(see Clearances, page 6). Note: This decora-

tive appliance is not designed for outdoor

installation.

2. The location should be in a place where drafts,

air conditioning ducts, windows or doors will

not affect fireplace heat output.

3. A location that avoids the cutting of joists

or roof rafters will make installation easier.

Figure 2 shows a typical two-sided fireplace

installation.

IMPORTANT:

All fireplace openings must be

located at least 3 feet from facing wall or com-

bustible material.

Existing
Side
Wall

4" From Opening to
Perpendicular Wall

Projected
Wall

Advertising
This manual is related to the following products: