GAS SUPPLY TESTING

Note:

This section is intended as a guide for quali-

fied technicians installing gas to this appliance.

CAUTION: Do not connect

appliance before pressure test-

ing gas piping. Damage to gas

valve may result and an unsafe

condition may be caused.

The appliance and its individual shut-off valve

must be disconnected from the gas supply piping

system during any pressure testing of that system at

test pressures in excess of 1/2 psig (3.5 kPa).
The appliance must be isolated from the gas sup-

ply piping system by closing its individual manual

shut-off valve during any pressure testing of the

gas supply piping system at test pressures equal

to or less than 1/2 psig (3.5 kPa).
This unit has been tested for installation at high

altitude in accordance with Canadian test stan-

dard CAN/CGA-2.17. Higher altitudes affect the

atmospheric pressure and heat valve of gaseous

fuels. When installing this unit at high altitudes,

the rated input will be lower than at sea level. The

lowered oxygen content in the air and the lowered

gas density require installation of a different size

orifice in order to achieve clean combustion of

the unit. Consult the unit data plate for the proper

high-altitude orifice size. Fill out the information

sticker attached to the unit when field converting.

See Specifications, page 15, when derating.

The gas control valve is secured to the burner pan

assembly underneath the front ledge. A 1/8" NPT

plugged tapping is provided on the gas control

valve for a test gauge connection immediately

upstream of the gas supply connection to the ap-

pliance (see Figures 13 and 14).

Figure 12 - Wiring Through Outer Surround

Figure 13 - Millivolt Control Valve

Figure 14 - Electronic Control Valve

ON/OFF
Knob

Pilot
Adjustment
Cap

Pilot Gas Line
Do Not Kink

Inlet
Pressure

Outlet
Pressure

To Main
Burner

To Pilot
Burner

E

A

From
Gas
Supply

To
Main
Burner

Inlet
Pressure

Outlet
Pressure

GAS LINE HOOK-UP

WARNING: Gas line hookup

should be done by your gas

supplier or a qualified service

person.

WARNING: Before you pro-

ceed, make sure your gas supply

is OFF.

A manual shutoff valve has been included in the

applianceʼs gas supply system. You may consider

installing an extra gas shutoff valve outside the ap-

plianceʼs enclosure (check with local codes) where

it can be accessed more conveniently with a key

through a wall as shown in Figure 15, page 10.
A 30" long, 1/2" NPT SCHD 40 flexible gas line

(supplied) may be used between the incoming 1/2"

NPT black iron gas line and the fireplace regulator

(located inside the firebox, under the access plate).

The incoming gas line may be routed toward the

appliance from either the left or right hand side of

fireplace outer surround.

Common
Ground Wire

Strain Relief
Grommet

Advertising
This manual is related to the following products: