CLEANING AND

MAINTENANCE

WARNING: Installation and

repair should be done by a quali-

fied service person. The appli-

ance should be inspected before

each use and at least annually

by a qualified service person.

More frequent cleaning may be

required due to excessive lint

from carpeting, bedding mate-

rial, pet hair, etc. It is imperative

that the control compartments,

burners and circulating air sys-

tem be kept clean.

WARNING: The logs can be

hot. Handle only when cool.

TO TURN OFF GAS

TO APPLIANCE

1. Turn off all electric power to the appliance

if service is to be performed.

2. Remove control access panel.

3. Close the gas valve.

OPERATING FIREPLACE

Continued

Figure 26 - Pilot

WARNING: Turn off gas and

electrical power before servicing

appliance. Any safety screen

or guard removed for servicing

must be replaced prior to operat-

ing the appliance.

WARNING: Failure to keep

the primary air opening(s) of

the burner(s) clean may result in

sooting and property damage.

Keep control compartment, logs, burner and area

surrounding logs clean by vacuuming or brushing

at least twice a year. Take care not to alter the set-

tings on the pilot assembly.
Do not use abrasive liquids or cleaners for cleaning

glass doors and trims. Any household glass cleaner

should suffice. Do not clean doors when hot. Allow

appliance to cool before cleaning.

TECHNICAL SERVICE

You may have further questions about installation,

operation or troubleshooting. If so, contact DESAʼs

Technical Service Department at 1-866-672-6040.

When calling please have your model and serial

numbers of your heater ready.
You can also visit DESAʼs Technical Services web

site at www.desatech.com.

SPECIFICATIONS

GL36ST, GL36STE
• Maximum Input Rating at Altitudes: 2,000 ft.

- 42,000 Btu/hr., 2,000 ft. to 4,000 ft. - 37,800

Btu/hr.

• Manifold Pressure: 3.5 W.C. (.87 kPa)
• Supply Pressure (in. of water): Minimum* - 4.5"

(1.12 kPa), Maximum - 11.0" (2.74 kPa)

• Orifice Size at Altitudes: 2,000 ft. - #30, 2,000 ft.

to 4,000 ft. - #31

GL36STP, GL36STEP
• Maximum Input Rating at Altitudes: 2,000 ft.

- 42,000 Btu/hr., 2,000 ft. to 4,000 ft. - 37,800

Btu/hr.

• Manifold Pressure: 11.0 W.C. (2.74 kPa)
• Supply Pressure (in. of water): Minimum* -

12.0" (2.89 kPa), Maximum - 13.0" (3.23 kPa)

• Orifice Size at Altitudes: 2,000 ft. - #49, 2,000 ft.

to 4,000 ft. - #51

* For the purpose of input adjustment