24 vdc power supply, Si5580, Si-1 indexer – Applied Motion Si5580 User Manual
Page 14

-14-
Connecting an Input to the Si-1 Motion Output
(Set Si-1 motion signal to “in position”. Si-1 will trigger Si5580 at end of each move).
Connecting a 3540i, Si3540, 7080i or MC8400
(When output closes, Si5580 input goes low).
Connecting an NPN Type Proximity Sensor to an Si5580 input
(When prox sensor activates, Si5580 input goes low).
Connecting a PNP Type Proximity Sensor to an Si5580 input
(When prox sensor activates, Si5580 input goes low).
Si5580
IN
IN/JOG COM
SI-1 indexer
MOTION+
MOTION–
5-24
VDC
Power
Supply
-
+
Si5580
IN
COM
Si3540, 7080i or MC8400
OUT+
OUT–
5-24
VDC
Power
Supply
-
+
Si5580
NPN
Proximity
Sensor
IN
COM
output
+
–
5-24
VDC
Power
Supply
-
+
NPN
Proximity
Sensor
IN
COM
output
+
–
5-24
VDC
Power
Supply
-
+
Si5580
PNP
Proximity
Sensor
IN
output
+
–
COM
5-24
VDC
Power
Supply
-
+
PNP
Proximity
Sensor
IN
output
+
–
COM
5-24
VDC
Power
Supply
-
+