Before you connect the servo drive to your system, 13 bluac5-si hardware manual – Applied Motion BLuAC5-Si User Manual

Page 13

Advertising
background image

13

BLuAC5-Si Hardware Manual

920-0035E

12/10/2014

Getting and Connecting an RS-485 2-wire adaptor to your PC

Model 485-25E from

Integrity Instruments

(800-450-2001) works well. It comes with every-

thing you need. Connect as follows:

adaptor drive

B

TX+/RX+

A

TX-/RX-

4-Wire RS-485 Figure #2

Before you connect the servo drive to your system

With the RS-232 cable connected between your PC and the Servo drive, on your PC, start
the SCL Setup Utility software. Select the proper comm port (1,2,3 or 4) then apply power to
the drive. Press the Caps Lock key. The drives only accept commands in uppercase. Type
RV then press ENTER. If the drive has power and is properly wired, it will respond with
“RV=x”. Where x is the firmware version of your drive. If the drive responds, you’re home
free: the RS485 network is functioning.

Next, you must choose an address for this drive. Any of the “low ASCII” characters (many of
which appear above the number keys on a PC keyboard) is acceptable:
! “ # $ % & ‘ ( ) * + , - . / 0 1 2 3 4 5 6 7 8 9 : ; < > ? @

To find out what address is in the drive now, type DA then press enter. The drive will respond
with DA=x, where x is the address that was last stored. (For example, the response might
be DA=@ or DA=!). To change the address, type DAy, where y is the new address character,
then press ENTER.

To test the new address, type yRV, then press ENTER. For example, if you set the address to
% and want to test that, type %RV. The drive should respond just as it does to RV, the global
revision level request.

Once the drive has been assigned an addresses, you can proceed with your SQL or Q Pro-
gramming mode application.

+ RX- + TX- GND

to PC TX+ /RX+ or A

to PC TX-/RX- or B

to PC GND

Drive #3

Advertising